Showing of 1 until 11 from 11 result(s)
Search for: Antonio J. A. da Costa
Abstract
Os cistos da fenda de Rathke são lesões para-selares, geralmente assintomáticas, presentes em 12 a 33% das autópsias de pacientes com hipófise normal. Ocasionalmente, os cistos podem aumentar de volume a ponto de comprimir estruturas supra-selares e intra-selares, levando ao aparecimento dos sintomas. Clinicamente, os pacientes referem escurecimento visual, além de apresentarem defeitos campimétricos. M.A.S.R., 47 anos, sexo feminino, branca, natural de Pelotas/RS com queixa de embaçamento progressivo da visão do olho direito há 2 meses. Ao exame, constatou-se baixa visual e hemianopsia bitemporal. A tomografia computadorizada evidenciou imagem hipodensa arredondada, de bordos nítidos, em topografia selar, determinando remodelação e alargamento da sela túrcica. A ressonância magnética mostrou lesão expansiva cística localizada na sela túrcica com crescimento supra-selar. A referida lesão apresenta obliteração da cisterna supra-selar e importante compressão sobre o quiasma óptico. A abordagem cirúrgica confirmou a presença de lesão expansiva cística comprimindo o quiasma óptico e o exame de anatomia patológica do material diagnosticou cisto da fenda de Rathke. O exame oftalmológico, três meses após a cirurgia, mostrou melhora da acuidade visual e recuperação total dos defeitos do campo visual. O cisto da fenda de Rathke deve ser incluído no diagnóstico diferencial dos tumores para-selares passíveis de causar compressão da via óptica nervosa e ressalta-se a importância do diagnóstico e tratamento precoce no intuito de prevenir danos estruturais com perdas irreversíveis da função visual, bem como os distúrbios endócrinos.
Keywords: Hemianopsia; Campo visual; Cistos; Sela túrcica; Doenças hipofisárias; Cultivo de tecido; Imagem por ressonância magnética
Abstract
OBJETIVOS: Comparar o desempenho visual e a análise de frente de onda entre as lentes intra-oculares (LIOs) multifocal difrativa Tecnis® ZM900 asférica e AcrySof® Restor® esférica SN60D3. MÉTODOS: Trata-se de estudo prospectivo comparativo que incluiu 78 olhos de 39 pacientes. A avaliação oftalmológica contou com medida da acuidade visual para longe, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste e análise de frente de onda por meio do aberrômetro OPD-Scan. RESULTADOS: Acuidade visual para longe e para perto sem correção óptica e análise de aberrometria foram estatisticamente semelhantes em relação a ambas as LIOs; já a visão intermediária e a sensibilidade ao contraste em condições fotópicas revelaram diferença estatisticamente significante entre as duas lentes a favor da Tecnis ZM900. CONCLUSÃO: Ambas as lentes intra-oculares promoveram excelente visão para longe e para perto em situações de alto contraste. A LIO Tecnis multifocal necessita de menos luminosidade para visão em situações de alto contraste, apresenta menos aberrações ópticas e melhor visão intermediária que a LIO ResTor.
Keywords: Lentes intra-oculares; Sensibilidades de contraste; Visão; Acuidade visual
Abstract
Keywords:
Abstract
Keywords:
Abstract
Keywords:
Abstract
Keywords:
Abstract
Keywords:
Abstract
OBJETIVOS: As características físico-químicas e o baixo custo da água de coco foram fundamentais para o este estudo. Analisar o uso de solução a base de água de coco como meio de conservação de córneas humanas em banco de olhos.
MÉTODOS: Estudo experimental e controlado realizado no Banco de Olhos do Hospital Geral de Fortaleza. Utilizou-se solução à base de água de coco preparada no laboratório de Tecnologia de Sêmen de Caprinos do Departamento de Medicina Veterinária da Universidade Estadual do Ceará. Foram usadas córneas de descartes divididas em dois grupos: G1 (Conservante com água de coco) - grupo experimental e G2 (grupo Conservante com OPTISOL GS®) grupo controle, em experimentos sequenciais. A osmolaridade do G1 foi analisada sequencialmente com 275, 300, 325, 345, 365 e 400 mOsm/L. A viabilidade das córneas foram realizadas por microscopia especular e biomicroscopia nos 1º, 3º e 7º dias.
RESULTADOS: As córneas em solução de 365 e 345 mOsm/L apresentavam transparência nos 8mm centrais até o 3º dia, com edema em toda periferia, dobras centrais e edema 2+, com perda parcial do epitélio até 7º dia, sendo o de maior osmolaridade com melhor transparência durante o seguimento. Grupo com 275, 300 e 400 mOsm/L, córnea opaca, edema difuso, perda total do epitélio no 3º dia. As córneas em Optisol mantiveram seus aspectos.
CONCLUSÕES: O conservante à base de água de coco manteve em parte a transparência corneana e a integridade epitelial, especialmente nos primeiros 3 dias de seguimento. A solução conservante com água de coco nas formulações utilizadas não se mostrou eficaz para o uso em banco de olhos humanos.
Keywords: Córnea; Água de coco; Preservação de órgãos/métodos; Solução para preservação de órgãos; Biotecnologia
Abstract
PURPOSE: Glaucoma is a chronic and progressive disease that requires long-term treatment and continuous monitoring. The Kahook Dual Blade, a device used to perform goniotomy in adults, is designed to improve intraocular pressure control in patients with glaucoma. This study aimed to evaluate the long-term efficacy and safety of kahook dual blade goniotomy in glaucoma patients undergoing cataract surgery over a 36-month follow-up.
METHODS: This was a retrospective case series including 56 eyes from 56 patients with mild-to-moderate primary open-angle glaucoma who underwent phacoemulsification combined with kahook dual blade goniotomy. Mean intraocular pressure values, number of preoperative and postoperative hypotensive eye drops, procedure survival, and complications were evaluated over 36 months. Surgical success was defined as either a reduction in intraocular pressure of ≥20% with intraocular pressure between 6 and 18 mmHg without additional medication or a reduction of ≥1 eye drop with intraocular pressure between 6 and
18 mmHg.
RESULTS: The mean preoperative intraocular pressure decreased from 15.96 ± 2,83) mmHg to 13.14 ± 2,11) mmHg at 36 months, representing a 14.9% reduction (p<0.001). The mean number of eye drops decreased from 1.91 ± 0,75) to 1.34 ± 0,92), a 29.8% reduction (p<0.001). The overall success rate was 69.6% at 36 months.
CONCLUSION: Kahook dual blade goniotomy combined with cataract surgery significantly reduced intraocular pressure and the number of hypotensive eye drops required in patients with mild-to-moderate primary open-angle glaucoma, with a favorable success rate maintained at 36 months.
Keywords: Glaucoma, open-angle/surgery; Gonioscopy/methods; Intraocular pressure/physiology; Lens implantation, intraocular; Phacoemulsification/methods; Trabeculectomy/instrumentation; Treatment outcome
Abstract
PURPOSE: Trachoma is the major infectious cause of preventable blindness in the world, and its sequelae include the presence of cicatricial entropion and trachomatous trichiasis. Trachoma can be corrected by surgical treatment of the eyelids and, if left untreated, may result in corneal opacification, low vision, and blindness. There are limited data on trachomatous trichiasis in Brazil. This study was conducted to estimate the frequency of entropion and trichiasis surgeries of trachomatous origin based on the records of procedures performed in specialized hospitals that served the Unified Health System (SUS) in the years 2016 and 2017.
METHODS: This was a retrospective study conducted in the oculoplastic sectors of the ophthalmology services of the following three hospitals in the state of São Paulo: Hospital das Clínicas da Faculdade de Medicina de Botucatu (HC Botucatu), Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (HC Ribeirão Preto), and Hospital Estadual de Bauru (HE Bauru). Medical records corresponding to the codes of interest were evaluated.
RESULTS: In total, 462 medical records were evaluated, including 170 (36.8%) at HC Botucatu, 61 (13.2%) at HE Bauru, and 231 (50.0%) at HC Ribeirão Preto. There were 39 (8.4%) cases of trachomatous trichiasis, ranging from 9 (14.8%) at HE Bauru to 15 (6.5%) at HC Ribeirão Preto.
CONCLUSIONS: The frequency of surgery due to trachoma was low in these oculoplastic services. The state of São Paulo might have reached the goal for trachoma elimination in the surgical component. The questionnaire used for data collection was successfully tested despite some difficulties in collecting data from the medical records. Studies with the same methodology are recommended in other services in the areas of endemic trachoma in the past to understand the frequency of eye lid surgeries performed for treating trachomatous sequelae.
Keywords: Trachoma; Trichiasis; Medical records; Epidemiology; Neglected diseases; Unified Health System; Brazil
Abstract
PURPOSE: Standard automated perimetry has been the standard method for measuring visual field changes for several years. It can measure an individual’s ability to detect a light stimulus from a uniformly illuminated background. In the management of glaucoma, the primary objective of perimetry is the identification and quantification of visual field abnormalities. It also serves as a longitudinal evaluation for the detection of disease progression. The development of artificial intelligence-based models capable of interpreting tests could combine technological development with improved access to healthcare.
METHODS: In this observational, cross-sectional, descriptive study, we used an artificial intelligence-based model [Inception V3] to interpret gray-scale crops from standard automated perimetry that were performed in an ophthalmology clinic in the Brazilian Amazon rainforest between January 2018 and December 2022.
RESULTS: The study included 1,519 standard automated perimetry test results that were performed using Humphrey HFA-II-i-750 (Zeiss Meditech). The Subsequently, 70%, 10%, and 20% of the dataset were used for training, validation, and testing, respectively. The model achieved 80% (68.23%–88.9%) sensitivity and 94.64% (88.8%–98%) specificity for detecting altered perimetry results. Furthermore, the area under the receiver operating characteristic curve was 0.93.
CONCLUSIONS: The integration of artificial intelligence in the diagnosis, screening, and monitoring of pathologies represents a paradigm shift in ophthalmology, enabling significant improvements in safety, efficiency, availability, and accessibility of treatment.
Keywords: Glaucoma; Disease progression; Perimetry; Visual Fields; Visual field tests; Artificial intelligence; Neural networks, computers; Machine learning
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000