Showing of 1 until 14 from 138 result(s)
Search for: Glaucoma; Drug price; Ophthalmic Solutions; Ophthalmic solutions; Instillationm, drug; Prostaglandins F, synthetic; Health care costs; Health expenditures; Comparative study
Abstract
Objetivo: Analisar a presença de microrganismos nos colírios de fluoresceína utilizados em um centro oftalmológico de referência em Recife-PE.
Métodos: Este estudo de vida real e mascarado avaliou colírios de fluoresceína utilizados na Fundação Altino Ventura em maio/2019. As culturas foram realizadas de acordo com os diferentes tempos de exposição: I - três frascos de colírio foram analisados após 1 dia de uso; II - três frascos de colírio após 4 dias de uso; III - três frascos de colírio após 8 dias de uso; IV - três garrafas fechadas foram usadas como grupo controle. As amostras foram coletadas da ponta do frasco, da gota instilada e do líquido residual interior. Após incubação, todas as colônias foram analisadas e identificadas através de testes bioquímicos.
Resultados: A taxa de contaminação dos frascos de colírio de fluoresceína neste estudo foi de 55,5% (5/9 frascos). Não houve contaminação no grupo controle. A maior contaminação foi observada os colírios expostos de um dia - 100% dos frascos. A ponta da garrafa teve uma maior taxa de contaminação em comparação com as culturas de gota e de fluido residual inferior. Bactérias gram-positivas foram isoladas em 7/27 amostras (25,9%). Não houve crescimento de fungos ou bactérias Gram-negativas.
Conclusão: A identificação de bactérias Gram-positivas predominantemente na ponta dos frascos de colírio de fluoresceína sugere manuseio inadequado como a principal causa de contaminação de colírios multidose.
Keywords: Fluoresceína; Soluções oftálmicas; Contaminação de medicamentos; Infecções oculares bacterianas/microbiologia.
Abstract
Objetivo: Comparar a viscotrabeculotomia com irrigação da câmara anterior com o implante de válvula de glaucoma de Ahmed para glaucoma secundário após remoção de óleo de silicone.
Métodos: Foi realizado um estudo prospectivo de 43 olhos pseudofácicos vitrectomizados com glaucoma persistente após a remoção de óleo de silicone. Os pacientes foram randomizados para viscotrabeculotomia com irrigação da câmara anterior ou implante de válvula de Ahmed. Todos os pacientes foram examinados no primeiro dia, na primeira semana e 1, 3, 6, 9, 12, 18 e 24 meses após a cirurgia. Observaram-se complicações pós-operatórias. O sucesso foi definido como uma pressão intraocular entre 6 e 20 mmHg e uma redução da pressão intraocular >30% em comparação com a pressão intraocular pré-operatória.
Resultados: Foram designados 22 olhos para o grupo da viscotrabeculotomia com irrigação da câmara anterior e 21 olhos para o grupo do implante de válvula de Ahmed. A pressão intraocular média pré-operatória foi de 35,5 ± 2,6 mmHg para o grupo da viscotrabeculotomia com irrigação da câmara anterior e pós- e de 35,5 ± 2,4 mmHg no grupo do implante de válvula de Ahmed. e Os valores pós-operatórios foram de 16,9 ± 0,7 mmHg e 17,9 ± 0,9 mmHg para esses mesmos grupos, respectivamente (p<0,0001). Ambos os grupos tiveram uma redução estatisticamente significativa da pressão intraocular em relação aos valores pré-operatórios (p<0,0001) em todos os momentos do acompanhamento. A taxa de sucesso não qualificado nos grupos da viscotrabeculotomia com irrigação da câmara anterior e do implante de válvula de Ahmed foi de 72,73% e 61,9%, respectivamente. A complicação mais comum foi o hifema, autolimitado e mínimo.
Conclusões: Tanto a viscotrabeculotomia com irrigação da câmara anterior quanto o implante de válvula de Ahmed são eficazes na redução da pressão intraocular no glaucoma após injeção de óleo de silicone, mas a viscotrabeculotomia com irrigação em câmara anterior proporcionou maior redução da pressão intraocular e maiores taxas de sucesso, com complicações mínimas.
Keywords: Implante para drenagem de glaucoma; Glaucoma; Descolamento retiniano; Óleo de silicone; Trabeculectomia; Injeção intravítrea; Pressão intraocular; Complicação pós-operatória; Solução oftálmica; Dexametasona; Ofloxacino.
Abstract
PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and “slow cook” transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma.
METHODS: We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B).
RESULTS: We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and “slow cook” transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the slow cook” and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the slow cook” transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and slow cook” transscleral cyclophotocoagulation, respectively (p<0.001).
CONCLUSION: Both techniques reduced intraocular pressure effectively.
Keywords: Sclera/surgery; Glaucoma, open-angle/surgery; Ciliary body/surgery; Intraocular pressure; Laser coagulation/methods; Lasers, semiconductor; Comparative study; Effectiveness
Abstract
Objetivos: Avaliar a percepção do risco de exposição da Doença de Coronavírus 2019 (COVID-19), conhecimento sobre medidas de proteção pessoal entre os profissionais de oftalmologia latino-americanos e priorização de pacientes com Covid-19.
Métodos: Pesquisa anônima voluntária autoadministrada (formulários do Google Drive) distribuída por mensagem de texto para profissionais de oftalmologia em 1º a 5 de maio de 2020.
Resultados: Trezentos e setenta e um profissionais completaram a pesquisa (taxa de resposta de 45%), composta por 118 residentes (27,6%), 111 oftalmologistas (40,5%) e 142 subespecialistas (32,8%). 106 profissionais (32,6%) sentiram-se em alto risco de adquirir o COVID-19 no trabalho. 273 (69,1%) acreditavam que as diretrizes atuais não são suficientes para identificar os pacientes com COVID-19. 265 (59,5%) não tinham treinamento para usar os equipamentos de proteção individual (EPI) e, mesmo com seu uso correto, 341 (91,5%) ainda se sentiram em risco de adquirir COVID-19. 80% consideraram que a equipe de trabalho não tem conhecimento de protocolos nacionais para o atendimento aos pacientes com COVID-19. Apenas 9 dos profissionais (2%) consideraram mudar a profissão para minimizar o risco de contágio por COVID-19.
Conclusão: Esta pesquisa mostra a escassez de pessoal e treinamento específico que os praticantes de oftalmologia na América Latina enfrentam em sua prática diária. Essas preocupações e ansiedade parecem ser as mesmas em todo o mundo com a pandemia de COVID- 19. É importante reforçar a confiança dos profissionais de oftalmologia nas diretrizes atuais de atendimento ao paciente com COVID-19 e também disponibilizar programas de treinamento sobre o uso de EPI e também itens de EPI disponíveis em todos os momentos para garantir a qualidade do atendimento e a disseminação mínima da doença.
Keywords: Pandemias; Oftalmologia; Pesquisas sobre serviços de saúde; América Latina; SARS-CoV2; Infecções por coronavirus; COVID-19
Abstract
OBJETIVO: Investigar a ação de colírios esteróides na doença de superfície ocular em pacientes a serem submetidos a cirurgia de trabeculectomia.
MÉTODOS: Foram incluídos 31 olhos de 31 pacientes com glaucoma em uso de pelo menos 3 medicações tópicas anti- hipertensivas há mais de 6 meses. Todos os pacientes foram tratados com colírio de etabonato de loteprednol 0,5% (1 gota a cada 6 horas) durante os 7 dias precedentes à cirurgia de trabeculectomia. Além disso, foram submetidos a exame oftalmológico completo e responderam questionário validado que visa avaliar parâmetros subjetivos correlacionados a doenças da superfície ocular (Ocular Surface Disease Index). Os aspectos clínicos avaliados foram: tempo de ruptura lacrimal, coloração da córnea após colírio de fluoresceína (ceratite) e hiperemia conjuntival. Os pacientes foram, ainda, submetidos à análise da superfície ocular através de novo
software tecnológico denominado “Keratographic”, tecnologia não invasiva que permite avaliar a doença da superfície ocular. A comparação da doença de superfície ocular antes e após a trabeculectomia foi avaliada estatisticamente através do teste pareado.
RESULTADOS: A média de idade dos participantes foi de 69,90 ± 10,77 anos. A AV média foi de 0,40 ± 0,34 logMAR. A taxa de prevalência global da Ocular Surface Disease Index foi de 27,20 ± 17,56 unidades. Em relação à avaliação clínica, não houve diferença significativa em relação hiperemia, ruptura lacrimal e ceratite antes e após a cirurgia (p>0,05 para todas as comparações). Em relação à análise com o “keratograph (menisco lacrimal, hiperemia, tempo de ruptura do filme lacrimal, meibografia para a pálpebra superior e inferior), os dois únicos parâmetros que diferiram significativamente antes e após a trabeculectomia, foram hiperemia e a média do tempo de rupture do filme lacrimal. Após a cirurgia de trabeculectomia, os pacientes apresentaram aumento da hiperemia conjuntival e diminuição do tempo de ruptura do filme lacrimal (p=0,013 e p=0,041, respectivamente).
CONCLUSÕES: O presente estudo, não somente confirma a elevada prevalência da doença de superfície ocular em pacientes com glaucoma, como também demonstra que a mesma pode ser mensurada objetivamente através de parâmetros mensurados pelo Keratograph. Apesar de ter utilizado etabonato de loteprednol 0,5% uma semana antes da cirurgia, nossa amostra apresentou piora da hiperemia conjuntival e diminuição no tempo de ruptura do filme lacrimal no pós-operatório.
Keywords: Glaucoma; Soluções oftálmicas; Doença de superfície ocular; Trabeculectomia
Abstract
Objetivo: Este estudo de qualidade e confiabilidade teve como objetivo identificar a variabilidade da massa do volume da gota de colírios multidose e verificar a existência de um padrão de referência para o volume da gota dos colírios usando lágrimas artificiais do mercado brasileiro.
Métodos: Cinco marcas de colírios lubrificantes foram avaliadas quanto ao volume da gota. Uma gota padrão ideal de 20 μL de cada fabricante foi coletada usando uma micropipeta ajustável. Os frascos dos colírios foram selecionados aleatoriamente e cinco medidas das massas das amostras foram coletadas usando escalas de precisão calibradas.
Resultados: A massa das amostras de 20 μL variou significativamente (p<0,001) entre os diferentes fabricantes. No entanto, entre os colírios da mesma marca, a variação da massa não foi estatisticamente diferente. A massa média global de todas as gotas pesadas foi de 18,24 mg e foi observada uma não-uniformidade entre todas as marcas de colírios.
Conclusão: Identificou-se uma variação significativa nas massas do volume das gotas dos colírios lubrificantes, usando equipamento padrão de laboratório. A heterogeneidade no volume da gota dos colírios testados sugere a existência de discrepâncias potenciais em suas posologias, possivelmente alterando a eficácia do tratamento. Uma medida de referência pré-estabelecida pode levar à produção de colírios com gotas de tamanho mais apropriado para uso em olhos humanos.
Keywords: Soluções oftálmicas/administração & dosagem; Volume da gota; Padrão de referência dos colírios; Padronização de colírios multidose; Administração de medicamentos oftálmicos; Qualidade
Abstract
PURPOSE: To evaluate the efficacy of different corticosteroid eye drop formulations (prednisolone acetate 1.0%, dexamethasone 1.0%, and loteprednol etabonate 0.5%) administered for different treatment durations (10 vs. 28 days) in controlling postoperative inflammation following uncomplicated cataract surgery.
METHODS: This randomized, masked clinical trial was conducted at the Instituto Cearense de Oftalmologia. Eligible participants were aged ≥50 yr and scheduled for routine cataract surgery. Exclusion criteria included preexisting ocular disease (elevated intraocular pressure, retinopathy, maculopathy, or uveitis) or concurrent medication use that could confound results. Patients were randomized to receive prednisolone acetate (1.0%), dexamethasone (1.0%), or loteprednol etabonate (0.5%) four times daily for 28 days (with tapering) or for 10 days. Medication bottles, prescriptions, and examiners were masked. Postoperative assessments included ocular symptoms, visual acuity, intraocular pressure, anterior chamber cell count and flare, pachymetry, endothelial cell density, and macular thickness over a 30-day follow-up.
RESULTS: A total of 140 eyes from 140 patients were analyzed (29 prednisolone acetate 1.0%, 18 dexamethasone 1.0%, and 21 loteprednol etabonate 0.5% for 28 days; 28 prednisolone acetate 1.0%, 22 dexamethasone 1.0%, and 22 loteprednol etabonate 0.5% for 10 days). No significant differences were found among the six groups during follow-up. However, eyes treated with dexamethasone (1.0%) showed greater intraocular pressure fluctuations, particularly on Days 7 and 30, and a higher incidence of rebound inflammation in the 28-day regimen. Structural cystoid macular edema without visual impact was observed in 5.9% of eyes in the 28-day groups and 14.2% of eyes in the 10-day groups, as detected by optical coherence tomography at 30 days.
CONCLUSION: Equivalent postoperative inflammation control can be achieved using different corticosteroid eye drop formulations at varying treatment durations following cataract surgery. Brazilian Registry of Clinical Trials (ReBEC): RBR-2frpntv
Keywords: Adrenal cortex hormones; Cataract; Cystoid macular edema; Corticosteroids; Inflammation; Loteprednol etabonate; Ophthalmic solutions; Postoperative period; Intraocular pressure; Visual acuity
Abstract
Objetivo: Determinar a relação entre doença da superfície ocular (OSD), número de medicamentos prescritos para o glaucoma, e como isso influencia na adesão ao tratamento.
Métodos: Neste estudo transversal, pacientes com glaucoma foram submetidos à coleta de dados demográficos, preenchimento do questionário Ocular Surface Disease Index e do Glaucoma Treatment Compliance Assessment Tool. Os parâmetros da superfície ocular foram avaliados pelo “Keratograph 5M”. Indivíduos foram estratificados em 2 grupos de acordo com a quantidade de colírios hipotensores oculares prescritos (Grupo 1: uma ou duas classes de medicamentos; Grupo 2: três ou quatro classes).
Resultados: No total, 27 olhos de 27 pacientes com glaucoma foram incluídos: 17 usando 1 ou 2 medicamentos tópicos (Grupo 1) e 10 olhos usando 3 ou 4 classes (Grupo 2). Na avaliação do Keratograph, os pacientes em uso de 3 ou mais medicamentos apresentaram altura do menisco lacrimal significativamente menor (0,27 ± 0,10 vs. 0,43 ± 0,22; p=0,037). Análise do questionário OSDI mostrou escores mais altos entre o grupo que usou mais colírios hipotensores (18,67 ± 13,53 vs. 38,82 ± 19,72; p=0,004). Em relação ao Glaucoma Treatment Compliance Assessment Tool, o Grupo 2 apresentou piores escores nos componentes de esquecimento (p=0,027) e barreiras por falta de colírios (p=0,031).
Conclusão: O estudo demonstrou que pacientes com glaucoma usando mais colírios hipotensivos apresentaram piores escores de altura do menisco lacrimal e Ocular Surface Disease Index, em comparação com aqueles que usaram menos medicamentos tópicos. Pacientes em uso de 3 ou 4 classes de colírios tiveram piores preditores de adesão ao glaucoma. Apesar dos piores resultados de doença da superfície ocular, não houve diferença significativa nos efeitos colaterais relatados.
Keywords: Adesão à medicação; Doenças da superfície ocular; Soluções oftálmicas; Glaucoma
Abstract
PURPOSE: This study aims to describe the technique, feasibility, efficacy, and safety of 360° trabeculotomy ab externo with double access for the treatment of congenital glaucoma.
METHODS: This paper provides a detailed description of the 360° trabeculotomy ab externo with double access used to treat pediatric glaucoma. The postoperative outcomes of six eyes from six patients who underwent this procedure for primary and secondary congenital glaucoma are also reported.
RESULTS: Six eyes from six patients were included in this study. The median age of the patients at the time of surgery was 1.25 yr (range: 0.27-5.41 yr). The mean preoperative intraocular pressure was 25 ± 5.87 mmHg (range: 18-35 mmHg). At baseline, the mean number of hypotensive eye drop medications used was 2 ± 0.63. Postoperatively, the mean intraocular pressure decreased to 10 ± 2.20 mmHg (range: 9-14 mmHg), and none of the patients required hypotensive eye drops. The most common postoperative complication was hyphema, observed in one case on the first postoperative day; however, it resolved within 7 days.
CONCLUSIONS: The 360° trabeculotomy ab externo with double access is a valuable addition to the surgical options for pediatric glaucoma. This technique facilitates a complete 360° ab externo opening of the trabecular meshwork while enhancing surgical safety.
Keywords: Glaucoma; Glaucoma/congenital; Trabeculectomy; Intraocular pressure; Ophthalmic solutions; Trabecular meshwork; Child
Abstract
Objetivo: Este estudo comparou o colírio de soro autólogo manipulado com metilcelulose a 0,5% com solução salina 0,9%. Critérios subjetivos de melhora dos sintomas e critérios clínicos objetivos para resposta à terapia foram avaliados.
Métodos: Este estudo prospectivo longitudinal envolveu 23 pacientes (42 olhos) com defeitos epiteliais persistentes ou doença de olho seco grave refratária à terapia convencional que usavam colírio de soro autólogo 20% preparado com metilcelulose por mais de 6 meses e iniciaram soro autólogo diluído em solução salina 0,9%. Os grupos controle e intervenção consistiam dos mesmos pacientes sob tratamentos alternados. Os critérios subjetivos para o alívio dos sintomas foram avaliados usando o Salisbury Eye Evaluation Questionnaire. Os critérios objetivos foram avaliados por meio de exame em lâmpada de fenda incluindo: tempo de ruptura da lágrima, coloração da córnea com fluoresceína, teste de Schirmer, coloração com rosa bengala e altura do menisco lacrimal. Esses critérios foram avaliados antes da troca do diluente e após 30, 90 e 180 dias.
Resultados: Um total de 42 olhos foram analisados antes e após 6 meses usando soro autólogo diluído com solução salina 0,9%. Nenhuma diferença significativa foi encontrada nos critérios subjetivos, tempo de ruptura da lágrima, menisco lacrimal, coloração com fluoresceína ou rosa bengala. Os resultados dos testes de Schirmer pioraram significativamente
em 30 e 90 dias (p=0,008). Não foram observadas complicações ou efeitos adversos.
Conclusões: Este estudo reforça o uso do colírio de soro autólogo 20% como um tratamento de sucesso para a doença do olho seco grave resistente à terapia convencional.
O soro autólogo diluído em solução salina a 0,9% não foi inferior à formulação de metilcelulose.
Keywords: Síndromes do olho seco; Ceratoconjuntivite seca; Síndrome de Sjögren; Solução salina; Soluções oftálmicas; Metilcelulose
Abstract
OBJETIVOS: À medida que a utilização de equipamentos digitais no emprego aumenta, a avaliação do seu efeito na saúde visual necessita de ferramentas válidas e robustas. Este estudo teve como objetivo traduzir, adaptar culturalmente e validar para português o Questionário da Síndrome Visual do Computador (CVS-Q©).
MÉTODOS: O procedimento foi realizado em 5 fases: tradução direta, síntese da tradução, tradução inversa, consolidação por um painel de especialistas, e pré-teste. Para fazer o pré-teste foi realizado um estudo piloto transversal aplicado a uma amostra de 26 participantes que completaram a versão pré-final da versão portuguesa do CVS-Q©, questionando por dificuldades, compreensão e sugestões de melhoria do questionário. Para avaliar a confiança e validade da versão portuguesa do CVS-Q©foi realizado um estudo transversal de validação em uma amostra diferente (280 funcionários).
RESULTADOS: No pré-teste, 96.2% dos participantes não apresentaram dificuldades no preenchimento do questionário, enquanto 84.0% indicaram que era claro e compreensível. Obteve-se, então, o CVS-Q© em português (Questionário da Síndrome Visual do Computador, CVS-Q PT©). A sua validação revelou uma boa consistência interna
da sua escala (Cronbach's alpha=0.793), boa estabilidade temporal (coeficiente de correlação interclasse=0.847; 95% CI 0.764-0.902, kappa=0.839), sensibilidades e especificidades adequadas (78.5% e 70.7%, respetivamente), boa capacidade de discriminação (área abaixo da curva=0.832; 95% CI 0.784-0.879), e uma adequada validade da convergência com o índice de doença da superfície ocular (ocular surface disease index - OSDI; coeficiente de correlação de Spearman=0.728, p<0.001). A análise fatorial revelou um único fator responsável por explicar a variância comum em 37.7%. Um funcionário com uma pontuação ≥7 pontos sofria de síndrome visual do computador.
CONCLUSÃO: O CVS-Q PT© pode ser considerada uma ferramenta intuitiva, de fácil interpretação e com boas propriedades psicométricas para avaliar a síndrome visual do computador em funcionários portugueses expostos a ecrãs digitais. Este questionário facilitará as decisões sobre medidas preventivas, intervenções e tratamento, e a comparação entre as populações expostas em diferentes países de língua portuguesa.
Keywords: Síndrome visual do computador; Dispositivos digitais; Saúde ocular; Estudo de validação; Propriedades psicométricas; Inquéritos e questionários
Abstract
PURPOSE: To evaluate the economic impact of the following initial treatment scenarios for glaucoma on the Brazilian Public Health System (SUS): (1) traditional continuous instillation of hypotensive eye drops and (2) single session of selective laser trabeculoplasty.
METHODS: Economic impact was analyzed in three scenarios, from the least to the most conservative, for a hypothetical cohort of 5,000 individuals with open-angle glaucoma. Thereafter, projections were made on the basis of a glaucoma prevalence of 3% in the 2021 Brazilian population size.
RESULTS: All three scenarios demonstrated that selective laser trabeculoplasty exhibited a significantly lower economic impact than the eye drops on SUS over one and five years. Furthermore, the difference was more than United States Dollar 8 billion at five years when considering 3% of the Brazilian population aged >40 years in 2021.
CONCLUSION: As the initial treatment for primary open-angle glaucoma, selective laser trabeculoplasty exhibited a lower economic impact on SUS than latanoprost and timolol maleate eye drop instillation in all the studied scenarios over one and five-year periods.
Keywords: Glaucoma; Trabeculotomy; Laser therapy; Cost analysis; Health care cost Unified Health System; Brazil
Abstract
A patient presented with corneoscleral thinning five months after the treatment of suspected ocular squamous surface neoplasia with mitomycin-C and interferon. For tectonic and aesthetic purposes, we decided to perform lamellar corneoscleral transplantation. The approach used established new tectonic support and corneal homeostasis. This technique might be an option in similar cases.
Keywords: Corneal diseases/diagnosis; Carcinoma, squamous cell; Conjunctival neoplasms/surgery; Interferon-alpha/therapeutic use; Mitomycin/therapeutic use; Ophthalmic solutions/administration & dosage; Humans; Case reports
Abstract
Ligneous conjunctivitis is a rare chronic form of recurrent membranous inflammation and plasminogen deficiency. Ocular manifestations may be associated with sites other than mucous membranes, such as the oral cavity, internal ear, respiratory, genitals, and kidney. Treatment is extremely difficult because of the lack of topic plasminogen drops, and a high volume is required for systemic supplementation. This report aimed to present two patients with ligneous conjunctivitis treated with membrane excision, topical fresh-frozen plasma, and heparin intra-, and postoperatively. No recurrence was found in the ligneous membrane in the 12-month follow-up. The use of topical fresh-frozen plasma and heparin after membrane excision could be effective to avoid recurrence.
Keywords: Conjunctivitis; Plasm; Heparin; Plasminogen; Ophthalmic solutions; Administration, ophthalmic
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000