Showing of 1 until 15 from 181 result(s)
Search for: Optic neuropathy, ischemic/diagnosis; Papilledema; Retinal perforations/therapy; Vitrectomy; Visual fields
Abstract
OBJETIVOS: Verificar a influência do campo visual e/ou tomografia de coerência óptica, quando analisados em associação à retinografia colorida, na diferenciação entre indivíduos com glaucoma daqueles com aumento fisiológico de escavação.
MÉTODOS: Oitenta pacientes com glaucoma ou aumento fisiológico de escavação (40 cada) foram randomizados de acordo com o exame testado (GI: retinografia colorida, GII: retinografia colorida + campo visual, GIII: retinografia colorida + tomografia de coerência óptica, GIV: retinografia colorida + campo visual + tomografia de coerência óptica). Vinte oftalmologistas não especialistas em glaucoma diagnosticaram glaucoma através de slides do PowerPoint, sem o exame direto do paciente.
RESULTADOS: A concordância interexaminador foi boa para o GII (ĸ: 0,63; 95%CI, 0,53-0,72), moderada para GIII (ĸ: 0,58; 95%CI, 0,48-0,68) e GIV (ĸ: 0,41; 95%CI, 0,31-0,51), e baixa para o GI (ĸ: 0,30; 95%CI, 0,20-0,39) (p<0,001). Acurácia diagnostica foi maior no GIII (15,8 ± 1,82) em comparação ao GI (12,95 ± 1,46, p<0,001) e o GII (16,25 ± 2,02) maior em comparação ao GI e GIV (14,10 ± 2,24) (para ambos, p<0,001). Para os pacientes com glaucoma, a acurácia diagnostica nos grupos GII e GIII foi superior do que em GI e GIV (ambos p<0,001). Sensibilidade e especificidade foram 59% e 70,5% no GI; 86,5% e 76% no GII, 86,5% e 71,5% no GIII; 68,5% e 72,5% no GIV, respectivamente. A acurácia foi maior no GII (81,3% [95%CI, 77,1-84,8]), seguido pelo GIII (79% [95%CI, 74,7-82,7]), GIV (70,5% [95%CI, 65,9-74,8]), e GI (64,8% [95%CI, 60,0-69,3]).
CONCLUSÕES: A avaliação isolada da retinografia colorida por oftalmologistas não especialistas em glaucoma não pode diferenciar pacientes com glaucoma daqueles com aumento fisiológico de escavação. Houve aumento da acurácia diagnóstica e da concordância interobservador com o acréscimo do campo visual ou da tomografia de coerência óptica. Entretanto, o uso de ambas as modalidades não melhorou a sensibilidade/especificadade.
Keywords: Glaucoma; Tomografia de coerência óptica; Testes de campo visual; Disco óptico; Variações dependentes do observador
Abstract
Objetivo: Analisar a camada plexiforme interna de células maculares e ganglionares e as espessuras da camada de fibras nervosas da retina após vitrectomia com técnica de flap invertido para orifício macular idiopático.
Métodos: Estudo prospectivo de 28 olhos submetidos à cirurgia de orifícios maculares idiopáticos. Foi realizada a técnica de flap invertido da membrana limitante interna usando Azul Brilhante (0,05%). Os exames oftalmológicos e a análise quantitativa da espessura do complexo de células maculares ganglionares foram analisados na linha de base com 1 mês e 3 meses após a cirurgia.
Resultados: A espessura média pré-operatória da camada plexiforme interna de células ganglionares e da camada plexiforme interna de células ganglionares ± camada de fibra nervosa da retina foi de 88,9 µm e 124,8 µm, respectivamente; a espessura média da camada plexiforme interna de células ganglionares com 1 mês e 3 meses após a cirurgia foi reduzida para 72,8 µm e 65,2 µm (p<0,001 e p<0,001, respectivamente). A espessura média da camada plexiforme interna de células ganglionares pós-operatórias + da camada de fibra nervosa da retina também foi reduzida com 1 e 3 meses (108,8 µm e 99,3 µm; p<0,001 e p<0,001, respectivamente). Nenhuma diferença significativa foi observada entre a acuidade visual melhor corrigida pré e pós-operatória com 1 e 3 meses (p <0, 73 e p<0, 14, respectivamente).
Conclusão: A camada plexiforme interna de células maculares ganglionares e a camada plexiforme interna de células ganglionares ± as espessuras da camada de fibra nervosa da retina foram significativamente reduzidas após vitrectomia com técnica de flap invertido usando azul brilhante (0,05%) para orifício macular idiopático.
Keywords: Células ganglionares da retina; Camada de fibras nervosas; Retina; Vitrectomia
Abstract
Objetivos: Investigar a incidência, fatores de risco e desfechos visuais do desenvolvimento da membrana epirretiniana após reparo do descolamento regmatogênico da retina.
Métodos: Trata-se de um estudo retrospectivo de 309 olhos submetidos à cirurgia inicial para descolamento regmatogênico da retina primário sem complicações. Os exames foram realizados no pré-operatório aos 1, 3, 6 e 12 meses pós-operatórios. Os pacientes foram divididos em dois grupos, dependendo da presença ou ausência de membrana epirretiniana.
Resultados: A incidência de membrana epirretiniana pós-operatória foi de 28,5%; 42,7% desses pacientes apresentaram desenvolvimento grave da membrana epirretiniana e, portanto, foram submetidos à remoção desta membrana. A regressão logística mostrou que as lágrimas retinianas gigantes (RC: 2,66; 95% IC: 1,045 - 6,792, p=0,040) e lágrimas em ferradura (RC: 0,534; 95% IC: 0,295-0,967, p=0,039), foram preditores significativos de membrana epirretiniana pós-operatória. A coloração com acetonida de triancinolona foi significativamente associada à prevenção da membrana epirretiniana (p=0,022). Trinta e quatro pacientes apresentaram acuidade visual melhorada, ou igual, ou acuidade visual final melhor corrigida; 4 olhos foram avaliados na consulta final de acompanhamento e apresentaram redução da acuidade visual melhor corrigida.
Conclusão: Nossa análise demonstra que as lágrimas de ferradura e as lágrimas retinianas gigantes representam fatores de risco para a membrana epirretiniana pós-operatória. A coloração com acetonida de triancinolona teve um efeito preventivo significativo na membrana epirretiniana no pós-operatório. Além disso, uma segunda rodada de vitrectomia pars plana, incluindo remoção da membrana, levou a uma melhora significativa da acuidade visual final melhor corrigida na última consulta de acompanhamento, embora a recuperação tenha sido limitada.
Keywords: Membrana epirretiniana; Descolamento da retina; Recurvamento da esclera; Acuidade visual; Vitrectomia
Abstract
OBJETIVO: Determinar o grau de deficiência visual em crianças com tumores da via óptica incapazes de informar a acuidade visual de reconhecimento.
MÉTODO: A acuidade visual de grades, em logMAR, foi estimada por potenciais visuais evocados de varredura em crianças com tumores das vias ópticas. O déficit da acuidade visual de grades binocular foi calculado em relação ao valor mediano normativo esperado para a idade e a deficiência visual, classificada como leve (0,10 a 0,39 logMAR), moderada (0,40 a 0,79 logMAR) ou grave (≥0,80 logMAR). Diferenças inter-oculares foram calculadas por subtração e consideradas aumentadas se >0,10 logMAR.
RESULTADOS: Foram avaliadas 25 crianças (13 meninos; média de idade ± DP=35,1± 25,9 meses; mediana=32,0 meses) com tumores da via óptica (24 gliomas e 1 tumor embrionário) localizados particularmente na transição hipotalâmico-quiasmática (n=21; 84,0%) e com anormalidades visuais detectadas pelos pais (n=17; 68,0%). A média do déficit da acuidade de grades foi 0,60 ± 0,36 logMAR (mediana=0,56 logMAR). Observou-se deficiência visual leve em 10 (40,0%), moderada em 8 (32,0%) e grave em 7 (28,0%), além de aumento da diferença interocular da acuidade visual (n=16; 64,0%). As principais alterações oftalmológicas encontradas foram: nistagmo (n=17; 68,0%), aumento da escavação do disco óptico e/ou palidez (n=13; 52,0%), estrabismo (n=12; 48,0%) e comportamento visual pobre (n=9; 36,0%).
CONCLUSÃO: Em crianças com tumor da via óptica e incapazes de responder aos testes de acuidade visual de reconhecimento, foi possível quantificar deficiência visual por meio dos potenciais visuais evocados de varredura e avaliar a diferença interocular da acuidade visual de grades. A gravidade do déficit da acuidade visual de grades relacionado à idade e a diferença interocular da acuidade visual de grades foram congruentes com alterações oftalmológicas e neuroimagem. O déficit da acuidade visual de grades foi útil à caracterização do estado visual em crianças com tumores da via óptica e ao embasamento da assistência neuro-oncológica.
Keywords: Transtornos da visão; Potenciais evocados visuais; Acuidade visual; Vias visuais; Glioma do nervo óptico; Criança
Abstract
Objetivos: A microperimetria tem sido usada há vários anos como uma forma de teste de função visual em pacientes com doenças da retina. Os valores normais de microperimetria obtidos com MP-3 ainda não foram totalmente publicados e os valores basais para sensibilidade macular topográfica e correlações com idade e sexo são necessários para estabelecer graus de comprometimento. O objetivo do trabalho é determinar valores para limiares de sensibilidade à luz e estabilidade de fixação usando o MP-3 em indivíduos normais.
Métodos: Trinta e sete voluntários saudáveis (idade: 28-68 anos), submetidos à microperimetria de limiar total usando uma estratégia de escada 4-2 (rápida) com o tamanho de estímulo padrão Goldmann III e 68 pontos de teste posicionados de forma idêntica aos do Humphrey Field Analyzer 10-2 grade de teste. A estabilidade da fixação foi registrada simultaneamente durante o teste de microperimetria. A relação entre a sensibilidade global e a idade foi calculada por meio de análise de regressão linear.
Resultados: A microperimetria foi realizada em 37 indivíduos (74 olhos). A sensibilidade média global foi de 29,01 ± 1,44 dB, intervalo: 26-31 dB. A mediana da sensibilidade central a 2° medida pelo MP-3 foi de 28,5 ± 1,77 dB (ER) e 28,75 ± 1,98 dB (OE). Os valores médios totais de estabilidade da fixação em 2° e 4° foram 80% e 96%, respectivamente. A análise de regressão linear também revelou um declínio de sensibilidade global relacionado à idade por ano de -0,051 dB ± 0,018 (ER) e -0,078 dB ± 0,021 (LE).
Conclusões: A microperimetria realizada com o MP-3 permite um exame automático, preciso e específico da topografia dos limiares de sensibilidade da retina. Os resultados deste estudo fornecem um banco de dados normal e de idade correspondente da microperimetria MP-3.
Keywords: Campos visual; Testes de campo visual; Retina; Microperímetro; Idade.
Abstract
Objetivo: Determinar as taxas de fechamento de buracos maculares idiopáticos grandes tratados com vitrectomia posterior e técnica de flap invertido 360 graus pediculado de membrana limitante interna, sem posicionamento de cabeça pós-operatório e definir melhora visual, tipos de fechamento do buraco macular e integridade das camadas retinianas externas como objetivo secundário.
Métodos: Este estudo foi uma série retrospectiva de casos. Todos os pacientes foram submetidos a vitrectomia com flap invertido 360 graus pediculado de membrana limitante interna e tamponamento com gás, sem posição de cabeça no pós-operatório. Idade, gênero, tempo de redução da acuidade visual, outras patologias oculares e status do cristalino foram compilados. Medida de melhor acuidade visual corrigida e tomografia de coerência óptica foram registradas durante as visitas de pré e pós-operatório (15 dias e 2 meses após cirurgia).
Resultados: Vinte olhos de 19 pacientes foram incluídos neste estudo. A idade média foi de sessenta e seis anos. Um total de 19 olhos (95%) atingiu fechamento do buraco, observado através das imagens de tomografia de coerência óptica após 2 meses de cirurgia. Melhor acuidade visual corrigida média aumentou +1,08 pré-operatória para +0,66 LogMAR em 2 meses de cirurgia (p<0,001), com média de 20 letras de melhora visual (0,4 LogMAR) na tabela do Early Treatment Diabetic Retinopathy Study. Dois tipos de fechamento do buraco foram observados: V (47,36%) e U (52,63%).
Conclusão: A técnica de flap invertido 360 graus pediculado de membrana limitante interna, sem posicionamento de cabeça no pós-operatório promoveu elevada taxa de fechamento (95%), reestabelecimento das camadas retinianas externas, fechamento com contorno foveal dos tipos V e U, além de melhora visual na maioria dos casos de BMI grandes (mesmo nos buracos maiores que 650 μm). Esta técnica pode representar uma alternativa para o tratamento de buracos maculares grandes em pacientes impossibilitados de cumprir o tradicional posicionamento de cabeça pós-operatório.
Keywords: Perfurações retinianas; Cuidados pós-operatórios; Vitrectomia; Cirurgia vitreorretiniana
Abstract
PURPOSE: Standard automated perimetry has been the standard method for measuring visual field changes for several years. It can measure an individual’s ability to detect a light stimulus from a uniformly illuminated background. In the management of glaucoma, the primary objective of perimetry is the identification and quantification of visual field abnormalities. It also serves as a longitudinal evaluation for the detection of disease progression. The development of artificial intelligence-based models capable of interpreting tests could combine technological development with improved access to healthcare.
METHODS: In this observational, cross-sectional, descriptive study, we used an artificial intelligence-based model [Inception V3] to interpret gray-scale crops from standard automated perimetry that were performed in an ophthalmology clinic in the Brazilian Amazon rainforest between January 2018 and December 2022.
RESULTS: The study included 1,519 standard automated perimetry test results that were performed using Humphrey HFA-II-i-750 (Zeiss Meditech). The Subsequently, 70%, 10%, and 20% of the dataset were used for training, validation, and testing, respectively. The model achieved 80% (68.23%–88.9%) sensitivity and 94.64% (88.8%–98%) specificity for detecting altered perimetry results. Furthermore, the area under the receiver operating characteristic curve was 0.93.
CONCLUSIONS: The integration of artificial intelligence in the diagnosis, screening, and monitoring of pathologies represents a paradigm shift in ophthalmology, enabling significant improvements in safety, efficiency, availability, and accessibility of treatment.
Keywords: Glaucoma; Disease progression; Perimetry; Visual Fields; Visual field tests; Artificial intelligence; Neural networks, computers; Machine learning
Abstract
PURPOSE: To evaluate the predictive value of initial intraocular pressure difference of the detached and fellow eyes of patients with complex rhegmatogenous retinal detachment on postoperative persistent ocular hypotony.
METHODS: This retrospective observational study included 538 eyes of 538 unilateral complex rhegmatogenous retinal detachment patients with a proliferative vitreoretinopathy grade of C-1 or higher, treated with silicone oil endotamponade following pars plana vitrectomy. The patients were divided into Group A (patients having silicone oil removal without ocular hypotony; n=504) and Group B (patients with persistent ocular hypotony following silicone oil removal [n=8, 23.5%] and with retained silicone oil [n=26, 76.5%] due to the risk of persistent ocular hypotony; total n=34). Ocular hypotony was defined as an intraocular pressure of <6 mmHg on two or more occasions. Patients' demographics, including age, sex, and follow-up time, and ocular characteristics, including ocular surgical and trauma history, initial and final best-corrected visual acuity, intraocular pressure and initial intraocular pressure difference of the detached and fellow eyes, and anatomical success rates and postoperative complications, were retrospectively collected from the electronic patient files.
RESULTS: The initial intraocular pressure was significantly lower in the detached eyes of Group B than in Group A (8.3 ± 3.5 vs. 12.9 ± 3.3, p<0.001). Also, the initial intraocular pressure difference was significantly higher in Group B than in Group A (8.9 ± 3.2 vs. 2.2 ± 2.7mmHg, p<0.001). The receiver operating characteristic curve analysis showed that the cutoff value of the initial intraocular pressure difference was 7.5mmHg for the risk of persistent ocular hypotony. The most influential factors on postoperative persistent ocular hypotony in the binary logistic regression analysis were the initial intraocular pressure difference and the need for a retinectomy.
CONCLUSION: In eyes with complex rhegmatogenous retinal detachment treated with pars plana vitrectomy and silicone oil tamponade, the initial intraocular pressure difference could be of value in predicting postoperative persistent ocular hypotony and could guide surgeons on the decision of silicone oil removal.
Keywords: Hypotony; Intraocular pressure; Pars plana vitrectomy; Retinal detachment; Silicone oils; Ocular hypotension; Visual acuity
Abstract
PURPOSE: To evaluate the saccadic movements of patients with visual field loss due to primary open-angle glaucoma.
METHODS: Thirteen patients with good visual acuity (0.2 logMAR or better) (seven patients with primary open-angle glaucoma 65 ± 13 years) and six controls (51 ± 6 years) yielded a comprehensive ophthalmological examination, including Humphrey Visual Field tests (SITA-Standard 24-2), and performed a monocular, exploratory digital visual search task that quantifies the duration for finding the number “4” on a random array of digits distributed on the screen. After individual adjustments of the angle and distance positioning, the screen was spatially matched with the 24-2 visual field, and divided into five areas for analysis. During the task, saccades were simultaneously recorded in the same eye with a video-based eye tracker.
RESULTS: The patients with primary open-angle glaucoma showed a significantly higher number of saccades/screen (median ± interquartile range, 59.00 ± 29.00 vs. 32.50 ± 19.75 saccades (p=0.027) and visual search time per screen (38.50 ± 60.14 vs. 23.75 ± 8.90 seconds (p=0.035) than the controls did. Although the univariate analysis indicated a significant correlation with visual field mean deviation (coefficient=26.19 (p=0.02), only the visual search time/screen was significantly associated with the number of saccades/screen in the multivariate regression model (coefficient=0.55 (p<0.001). Overall, no significant correlation was observed between the sectorial number of saccades and the sensitivity of the five visual field areas.
CONCLUSIONS: The patients with primary open-angle glaucoma show impaired search performance and showed a higher number of saccades needed to find stimuli when performing the exploratory visual task.
Keywords: Glaucoma, open angle; Saccades; Eye movements; Visual fields; Vision disorders
Abstract
A Neurite óptica é uma importante causa de diminuição da visão devido à inflamação do nervo óptico. Por apresentar diversas etiologias faz-se necessário ampla investigação. A neuropatia óptica autoimune corresponde a uma doença rara que se manifesta com perda visual aguda, indolor e grave. A gravidade está associada a sua fisiopatogenia com componentes inflamatório e isquêmico. A positividade para marcadores de doenças autoimunes, mais comumente a elevação da titulação de anticorpos antinucleares, são fatores determinantes para o diagnóstico da neuropatia óptica autoimune. O tratamento é feito através de imunossupressão, com necessidade de altas doses de corticoide. Neste relato iremos descrever um paciente com neuropatia óptica autoimune. Discutiremos sobre a importância dos parâmetros laboratoriais e os achados de imagem da ressonância magnética para o diagnóstico.
Keywords: Neuropatia óptica autoimune; Neurite óptica; Desordem do espectro; Neuromielite óptica; Imagem de difusão por ressonância magnética; Neurite óptica
Abstract
O coloboma ocular é o resultado de um fechamento impróprio da fissura embrionária. As drusas da cabeça do nervo óptico são depósitos hialinos localizados anteriormente à lâmina cribosa que crescem e se calcificam com o tempo. A associação de ambos é rara, com apenas dois casos descritos na literatura. Apresentamos um paciente com coloboma irido-coriorretiniano e limites do nervo óptico mal definidos em seu olho direito, e aumento da ramificação vascular papilar e atrofia peripapilar em seu olho esquerdo, sem drusas visíveis. Autofluorescência de fundo, tomografia de coerência óptica de alta resolução e ultrassonografia B-scan foram realizadas confirmando o diagnóstico de drusas enterradas bilaterais da cabeça do nervo óptico. A associação entre colobomas irido-coriorretinianos com drusas do nervo óptico na ausência de doença sistêmica é excepcional. Nosso caso demonstra a importância da imagem multimodal para o diagnóstico correto de drusas enterradas de cabeça do nervo óptico.
Keywords: Coloboma; Retina/anormalidade; Doença do nervo óptico; Drusas do disco óptico; Tomografia de coerência óptica; Acuidade visual; Humano; Relato de caso
Abstract
Este artigo relata o caso de um paciente do sexo masculino, 11 anos de idade, com história de proptose e baixa de acuidade visual progressiva. Ao exame oftalmológico apresentava melhor acuidade visual de 20/25 em olho direito e percepção de luz em olho esquerdo. Existia exotropia e limitação à adução no olho esquerdo. À campimetria automatizada, observou-se quadrantopsia temporal inferior em olho direito e escotoma total em olho esquerdo. À ressonância magnética, evidenciou-se lesão expansiva em trajeto do nervo óptico esquerdo estendendo-se até região do tronco encefálico, com acometimento quiasmático. O objetivo deste artigo é relatar o glioma de vias ópticas, bem como discutir os achados e sua interligação com a literatura atual.
Keywords: Glioma; Neoplasias do nervo óptico; Quiasma óptico; Astrocitoma; Imageamento por ressonância magnética; Acuidade Visual; Relatos de casos; Humanos.
Abstract
Relatamos o caso de uma jovem com diminuição da visão do olho direito. Um mês antes do primeiro atendimento, a paciente desenvolveu pré-eclâmpsia grave com 22 semanas de gestação e interrompeu a gravidez. O exame de fundo revelou manchas algodonosas e exsudatos duros na mácula em ambos os olhos, com uma mancha amarela no centro da fóvea do olho direito. A tomografia de coerência óptica mostrou um buraco macular de espessura total com bordas cistoides elevadas no olho direito. A paciente foi diagnosticada com buraco macular secundário a pré-eclâmpsia e acompanhada para fechamento espontâneo. Um mês após a primeira visita, foi-lhe sugerida a intervenção cirúrgica, devido a um declínio em sua visão. Três meses depois, o paciente aprovou a cirurgia e foi submetida a uma vitrectomia via pars plana com retalho invertido de membrana limitante interna e tampão interno C3F8, o que proporcionou uma melhora anatômica e visual.
Keywords: Perfurações retinianas; Vitrectomia; Cirurgia vitreorretiniana; Pré-eclampsia; Tomografia de coerência óptica.
Abstract
Uma mulher de 71 anos de idade apresentou neuropatia óptica isquêmica anterior não arterítica no nervo óptico com fibras nervosas peripapilares mielinizadas previamente registradas. Seu histórico médico foi significativo para hipertensão arterial sistêmica controlada, hiperlipidemia e diabetes mellitus. Em ambos os discos ópticos, a tacícula fisiológica esteve ausente. A neuropatia óptica isquêmica anterior não arterítica afetou principalmente os setores temporal e inferior da camada de fibras nervosas da retina peripapilar, como demonstrado pela tomografia de coerência óptica da camada de fibras nervosas da retina e pela angiotomografia de coerência óptica do disco óptico. Ao contrário de outros relatórios publicados, apenas uma ligeira regressão das fibras nervosas mielinizadas foi observada após um ano de acompanhamento. Isto pode ser explicado pelo fato da isquemia ter afetado principalmente os setores temporal e inferior peripapilares, enquanto as fibras nervosas de mielina eram nasal superior ao disco óptico.
Keywords: Neuropatia óptica isquêmica; Fibras nervosas mielinizadas; Doenças do nervo óptico; Tomografia de coerência óptica; Neovascularização retiniana; Acuidade visual; Humanos; Relato de casos
Abstract
Optic neuritis is an important cause of unilateral and acute visual loss in young adults, but other differential diagnoses should be considered, especially when the disease has an atypical presentation. This report presents the case of a young woman with reduced visual acuity in her right eye, associated with optic disc edema and a relative afferent pupillary defect, that was initially misdiagnosed as optic neuritis and subsequently found to have paracentral acute middle maculopathy, possibly secondary to subtle impending central retinal vein occlusion. This case emphasizes the need to remember that retinal vascular diseases can occasionally mimic optic neuritis. Detailed anamnesis and ophthalmic examination can avoid unnecessary interventions.
Keywords: Optic disc; Papilledema; Optic neuritis; Retinal diseases; Diagnosis, differential; Visual acuity; Diagnostic errors