Showing of 1 until 15 from 263 result(s)
Search for: Keratoconus; Sleep apnea, obstructive; Risk factors; Body mass index; Sleep; Logistic models; Patient acuity; Tomography; Surveys and questionnaires
Abstract
Objetivo: Este estudo tem como objetivo avaliar a eficácia de lentes de contato híbridas de nova geração nos resultados visuais e na qualidade de vida relacionada à visão em pacientes com ceratocone com intolerância ou insucesso dos métodos de correção habituais, tais como lentes flexíveis de silicone-hidrogel ou rígidas permeáveis a gases.
Métodos: Foram incluídos neste estudo transversal prospectivo 42 olhos de 28 pacientes com ceratocone. Uma lente Airflex (Swisslens) foi aplicada nos olhos de acordo com as instruções do fabricante. Um exame oftalmológico, incluindo refração manifesta, melhor acuidade visual corrigida para longe, biomicroscopia com lâmpada de fenda e a aplicação do National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25), foi realizado no início do estudo e na visita de 6 meses.
Resultados: Foi possível obter um ajuste adequado em 39 olhos (92,9%) de 26 pacientes. Foram excluídos do estudo 6 olhos de 3 pacientes devido à cessação do uso de lentes. A idade média dos usuários bem-sucedidos era de 20,3 ± 4,9 anos. A média da melhor acuidade visual corrigida para longe foi melhorada estatisticamente de 0,62 ± 0,30 para 0,11 ± 0,06 logMAR com as lentes de contato híbridas Airflex (p<0,001). A pontuação média geral composta no questionário NEI-VFQ-25 aumentou de forma estatisticamente significativa com a lente de contato híbrida Airflex na visita de 6 meses, em comparação com a pontuação inicial (de 77,1 ± 16,3 para 90,9 ± 7,3, p=0,036). As lentes de contato híbridas Airflex apresentaram pontuações melhores com significância estatística em todos os itens das sub-escalas do NEI-VFQ-25 (todos com p<0,05). Nenhum efeito adverso significativo foi observado.
Conclusões: Lentes de contato híbridas de nova geração podem ser usadas como uma alternativa eficaz para a correção do astigmatismo irregular em pacientes com ceratocone com intolerância ou insucesso dos métodos habituais. Com essas lentes, pode-se alcançar uma melhora significativa na qualidade de vida relacionada à visão em pacientes com ceratocone.
Keywords: Lentes de contato; Ceratocone; Refração ocular; Acuidade visual; Qualidade de vida; Inquéritos e questionários
Abstract
PURPOSE: To analyze the quality of life and treatment adherence of patients with glaucoma at different disease stages, considering factors such as sex, visual acuity, disease severity, and treatment characteristics.
METHODS: This cross-sectional study included 174 patients (346 glaucomatous eyes) recruited from clinical records and routine follow-ups at a specialized ophthalmology center. Their mean age was 39–90 years, and 60.9% of them were women. Their quality of life and adherence were assessed using the NEI-VFQ25 and MMAS-8 questionnaires, respectively. Complementary tests included 24:2 visual field test, retinography, and optical coherence tomography. Patients diagnosed with glaucoma for at least 6 months were included, whereas pregnant patients and those with ocular diseases were excluded.
RESULTS: Among the participants, 59.2% adhered to the treatment whereas 40.8% showed low adherence. The mean quality of life score was 81.87. Patients with low adherence had slightly higher quality of life scores (mean 83.1) than those with good adherence (mean 81.0), but the difference was not statistically significant. Disease severity was associated with increased optic nerve cupping, reduced thickness of the nerve fiber and ganglion cell layers, and great visual field loss. No significant correlation was observed between adherence and quality of life, indicating the independence of these factors and the influence of psychological or social elements.
CONCLUSION: The absence of a correlation between quality of life and treatment adherence highlights the need for tailored interventions for psychological and social aspects. These findings indicate the importance of a comprehensive approach to managing glaucoma, preserving visual function, strengthening doctor–patient relationships, and considering psychosocial factors to enhance quality of life and treatment adherence.
Keywords: Glaucoma; Quality of life; Patient health questionnaire; Patient acuity; Antiglaucoma agents; Visual acuity; Treatment adherence and compliance; Surveys and questionnaires
Abstract
OBJETIVO: Comparar a gravidade e a lateralidade do ceratocone de acordo com a rinite alérgica, os hábitos de coçar e dormir e a destreza manual.
MÉTODOS: Foram realizadas questões objetivas sobre rinite alérgica, prurido ocular e posição do sono em pacientes com ceratocone, diagnosticados com base na tomografia corneana. Esses exames foram analisados e classificados de acordo com a classificação de Amsler-Krumeich.
RESULTADOS: O prurido ocular foi referido por 29 (85,29%) dos 34 voluntários. Dezoito sujeitos (62,07%) relataram coçar ambos os olhos igualmente, 6 (20,69%) mais no olho direito e 5 (17,24%) mais no olho esquerdo. Comparando-se a posição de dormir principal e o olhos com apresentação mais grave da doença, foi encontrada alguma relação baseada no teste exato de Fisher (0,567 no olho direito e 0,568 no olho esquerdo), embora nenhuma comparação parecesse estatisticamente significante.
CONCLUSÕES: A associação entre maiores valores de ceratometria e posição do sono parece ser mais importante do que entre ceratometria e prurido ou destreza manual.
Keywords: Ceratocone; Hipersensibilidade; Sono/fisiologia; Rinite alérgica; Córnea; Tomografia
Abstract
PURPOSE: To analyze the association between corneal tomography patterns and atopic conditions in children and adolescents, and to investigate the relationship between corneal tomography findings, sleeping position, and dominant hand.
METHODS: Patients aged 8–16 yr underwent ocular and immunological examinations, including biomicroscopy, corneal tomography, the International Study of Asthma and Allergies in Childhood questionnaire, and an allergy skin test. Based on immunological results, participants were assigned to either the Control Group or the Atopic Group. Tomographic indices were analyzed alongside information on ocular itching, sleeping position, and dominant hand.
RESULTS: A total of 158 patients (mean age: 10.72 ± 2.13 yr) were evaluated, including 34 (21.52%) in the Control Group and 124 (78.48%) in the Atopic Group. Abnormal tomography was observed in 25 patients (15.82%), while 133 (84.18%) had normal results. Comparison between the Control and Atopic Groups regarding ocular itching episodes revealed a statistically significant difference (p≤0.05). Dominant hand and sleeping position showed no statistically significant associations with group classification, tomography results, or ocular itching.
CONCLUSION: Systemic allergies are strongly associated with biomechanical and structural corneal changes, which may or may not progress to different keratoconus patterns. No association was found between eye rubbing and any tomographic parameter, nor between sleeping position or hand dominance and tomography findings.
Keywords: Adolescent; Child; Hypersensitivity; Hypersensitivity, immediate; Cornea; Skin tests; Sleep; Tomography.
Abstract
OBJETIVO: O objetivo deste estudo foi avaliar os parâmetros da cabeça do nervo óptico e a espessura da camada interna da retina em crianças e adolescentes obesos.
MÉTODOS: Quarenta e um olhos de 41 participantes pediátricos obesos e 41 olhos de 41 controles saudáveis pareados por idade e sexo foram incluídos neste estudo. O índice de massa corporal foi calculado com base no sexo e na idade, utilizando medidas de peso e estatura corporal. Os valores de lipídios no sangue (colesterol, lipoproteína de baixa e alta densidade e triglicérides) foram medidos nos participantes obesos. A tomografia de coerência óptica foi usada para examinar os parâmetros da cabeça do nervo óptico, incluindo a área da borda, área do disco, razão escavação/disco, volume da escavação, espessura s camadas de fibra nervosa da retina e as camadas plexiformes internas das células ganglionares da mácula.
RESULTADOS: Os parâmetros do disco óptico foram semelhantes em crianças obesas e saudáveis (p>0,05). A porcentagem da simetria da espessura da camada de fibras nervosas da retina binocular foi significativamente diferente entre os grupos obesos e controle (p=0,003). Comparados ao grupo controle, os participantes do grupo obeso exibiram camadas mais finas de fibras nervosas da retina nos quadrantes superiores (p=0,04) e camadas plexiformes mais finas da célula ganglionar interna nos setores temporal superior (p=0,04). Não houve correlação significante entre os parâmetros oculares e os valores dos exames de sangue lipídico avaliados neste estudo (p>0,05). O índice de massa corporal foi significativamente correlacionado negativamente com a espessura média da camada de fibras nervosas da retina (r=-0,33, p=0,03) no grupo obeso. Não houve correlação significativa entre a pressão intraocular e o índice de massa corporal (r=0,05, p=0,74).
CONCLUSÃO: Comparadas às crianças saudáveis, as crianças obesas apresentaram maior assimetria binocular na espessura da camada de fibras nervosas da retina e fibras nervosas da retina mais finas e camadas plexiformes internas das células ganglionares em vários setores. Os níveis de lipídios no sangue não foram associados à espessura da retina ou aos parâmetros do disco óptico em crianças obesas.
Keywords: Células ganglionares da retina; Disco óptico; Fibras nervosas; Obesidade pediátrica; Adolescente; Índice de massa corporal
Abstract
Objetivo: Avaliar a prática e tratamento da ptose da pálpebra superior por membros das sociedades latino-americanas e espanhola de Cirurgia Plástica Ocular.
Métodos: Os membros das referidas sociedades foram convidados por e-mail para responder a um questionário eletrônico garantindo o anonimato. O questionário constou de dados demográficos do cirurgião e outras quatro seções: avaliação pré-operatória da ptose da pálpebra superior, preferências cirúrgicas, conduta pós-operatória e complicações. Estatística descritiva foi utilizada para análise da frequência e proporções percentuais.
Resultados: Trezentos e cinquenta e quatro experientes cirurgiões oculoplásticos dos quais 47,7% realizam mais de 20 cirurgias de ptose da pálpebra superior por ano responderam ao questionário. Na avaliação pré-operatória, 68,9% realizam testes para olho seco, mas o teste da fenilefrina é feito por menos da metade dos entrevistados (47,4%). A ptose da pálpebra superior leve geralmente é corrigida por conjuntivo-mullerectomia (43,6%), a ptose da pálpebra superior grave por cirurgia do músculo frontal (57%) ou ressecção da aponeurose do levantador via anterior, principalmente usando a supramáxima (17,5%). O principal motivo para operar a ptose congênita grave é o risco de ambliopia (37,3%). A ptose involucional associada à dermatocálase costuma ser corrigida pela via anterior (63,3%). Hipocorreção é complicação comum após a ressecção da aponeurose do levantador (40%) ou suspensão ao frontal (27,5%).
Conclusões: As práticas atuais dos cirurgiões oculoplásticos espanhóis e latino-americanos para diagnóstico e tratamento de ptose da pálpebra superior foram relatadas. Os dados apresentados podem ser usados para comparar a abordagem dos cirurgiões com a de seus pares.
Keywords: Blefaroptose/diagnóstico; Ambliopia; Fenillefrina; Inquéritos e questionários; Demografia; Cirurgiões.
Abstract
Objetivo: Determinar se codeína (30 mg) mais paracetamol (500 mg) após ceratectomia fotorrefrativa fornece efeitos benéficos sobre a qualidade do sono, níveis de atividade e ingestão de alimentos além de seu efeito analgésico.
Métodos: Quarenta pacientes (80 olhos) foram incluídos neste estudo randomizado, duplo-cego, pareado, placebo-controlado, add-on. Cada olho foi tratado com 2 semanas de intervalo, sendo aleatoriamente alocado para placebo ou intervenção (4x/dia durante 4 dias). Os resultados incluíram a qualidade do sono, atividade diária e ingestão de alimentos dentro de 24-72 horas de pós-operatório, conforme medido pelo McGill Pain Questionnaire.
Resultados: A qualidade do sono e os níveis de atividade foram inversamente associados aos escores de dor nas primeiras 48 horas após o ceratectomia fotorrefrativa. Durante a intervenção, os pacientes foram significativamente mais propensos a classificar seu sono como bom em 24 horas (risco relativo=2,5, intervalo de confiança de 95%: 1,48-4,21, p<0,001) e 48 horas comparado ao placebo (risco relativo=1,37, intervalo de confiança de 95%: 1,03-1,84, p=0,023). A probabilidade de relatar bons níveis de atividade em 24 e 72 horas após ceratectomia fotorrefrativa também foi significativamente maior durante a intervenção em comparação com placebo (risco relativo=3,0, intervalo de confiança de 95%: 1,49-6,15, p=0,006 e risco relativo=1,31, intervalo de confiança de 95%: 1,02 -1,67, p=0,021, respectivamente). Nenhuma diferença foi observada entre a intervenção e placebo em relação à alimentação oral.
Conclusão: A combinação de codeína e paracetamol melhorou significativamente a qualidade do sono e atividades diárias nas primeiras 24-72 horas após o ceratectomia fotorrefrativa em comparação com placebo.
Keywords: Codeina; Ceratectomia fotorrefrativa; McGill Pain Questionnaire; Dor; Acetaminofen; Sono; Atividades cotidianas
Abstract
PURPOSE: This study aimed to examine factors related to the professionalism of ophthalmology residents.
METHODS: A cross-sectional study was carried out involving 48 ophthalmology residents in Brazil. Professionalism was assessed using the professionalism mini-evaluation exercise, completed by both preceptors and residents, and the Pennsylvania State College of Medicine Professionalism Questionnaire, completed by the residents. The association between the professionalism score assigned by the preceptor through the professionalism mini-evaluation exercise and various sociodemographic and educational variables was assessed. The correlation between the residents’ self-assessment across both instruments and the preceptor’s assessments was measured using Spearman’s Rho.
RESULTS: All 48 residents were included, with equal representation across the 3 years of residency. The majority were female (58.3%) and between 25 and 29 years old (66.7%). The average professionalism score on the professionalism mini-evaluation exercise given by the preceptors was 3.0 (75%). A significant association was found between the year of training and the score in the doctor-patient relationship domain, with first-year residents showing lower scores (p=0.002). Male residents had higher scores in the “Interprofessional” domain (p=0.031). Graduates from private medical schools scored higher in both the “doctor-patient relationship” (p=0.015) and “reflective skills” (p=0.033) domains. Lower interest in professionalism was linked to lower scores in the “Interprofessional relationships” (p=0.033) and “time management” (p=0.003) domains. A strong correlation was observed between preceptor’s professionalism mini-evaluation exercise scores and residents’ self-assessed professionalism mini-evaluation exercise scores (r=0.917). However, the correlation between the self-assessed professionalism mini-evaluation exercise and the Pennsylvania questionnaire scores was weak (r=0.226).
CONCLUSION: Professionalism scores among ophthalmology residents were associated with year of training, gender, type of undergraduate education, and level of interest in the topic.
Keywords: Internship and residency; Ophthalmology; Professional competence; Education, professional; Physician-patient relations; Surveys and questionnaires
Abstract
Objetivos: Validar a versão em português do Catquest-9SF através de sua aplicação em uma população nativa do Brasil com catarata e determinar a correlação da pontuação obtida no questionário com a acuidade visual pré-operatória.
Métodos: Realizou-se um estudo prospectivo para validação de questionário. O Catquest-9SF foi traduzido e retro traduzido gerando uma versão final em português. Um total de 120 pacientes brasileiros que aguardavam realização de cirurgia de catarata foram recrutados para responder ao questionário e para documentação de dados pré-operatórios e acuidade visual. Análise Rasch foi utilizada para acessar as propriedades psicométricas do instrumento.
Resultados: A versão em português do Catquest-9SF demonstrou ajuste aceitável dos itens (item fit statistics variando entre 0,7 e 1,3), unidimensionalidade (Principal Component Analisis) e boa organização nas categorias de resposta dos itens (limiares das categorias: -2,79; 0,57; 2,22). O questionário contém itens com relação estável, se considerado um mesmo nível de deficiência visual, na comparação entre dois grupos (ausência de differential item functioning). Existe adequada separação de pessoas (Person Separation Index 3,07). A acuidade visual em LogMAR no melhor olho com melhor correção óptica mostrou correlação estatisticamente significativa com a pontuação
em logit do Catquest-9SF (r=0,282 e p=0,004).
Conclusões: A versão em português do Catquest-9SF apresenta evidência de validade e confiabilidade, além de ser linguística e culturalmente compreensível para pacientes de língua portuguesa naturais do Brasil. Trata-se de questionário de fácil entendimento e rápida aplicação, sendo capaz de estimar de maneira adequada o funcionamento visual subjetivo em pacientes com catarata. Existe correlação significativa com a acuidade visual e a pontuação obtida no questionário.
Keywords: Extração de catarata; Perfil do impacto da doença; Acuidade visual; Inquéritos e questionários; Qualidade de vida.
Abstract
PURPOSE: This clinical study aimed to assess the effectiveness of microemulsion artificial tears containing povidone and propylene glycol in the management of dry eye disease. Secondary objectives included evaluating improvements in tear-film stability, measured by tear break-up time and corneal staining scores, along with the tolerability and safety of the formulation.
METHODS: This was a prospective, single-arm interventional study involving 30 participants (52 eyes) diagnosed with dry eye disease. Participants self-administered the investigational eye drops twice daily for 28 consecutive days. Primary and secondary outcomes included changes in the Ocular Surface Disease Index, tear break-up time, and corneal staining scores. Adverse events were documented throughout the study period.
RESULTS: Significant improvements in Ocular Surface Disease Index scores were observed, reflecting a reduction in dry eye disease symptoms. Tear break-up time increased notably between baseline and follow-up assessments, with the proportion of eyes exhibiting tear break-up time ≥10 srising from 25.0% to 63.5%. Additionally, the percentage of eyes with a corneal staining score of zero improved from 23.1% to 69.2%. Conjunctival staining also decreased, with the proportion of eyes with scores of 2 and 3 dropping from 11.5% to 3.8% and 5.8% to 0%, respectively.
CONCLUSIONS: The findings suggest that povidone and propylene glycol-based artificial tears significantly enhance tear-film stability and alleviate symptoms in patients with mild to moderate dry eye disease, with minimal adverse effects. This formulation represents a safe and effective short-term treatment option for dry eye disease management.
Keywords: Artificial tears; Dry eye disease; Tear-film stability; Propylene glycol; Povidone; Visual acuity; Surveys and questionnaires
Abstract
PURPOSE: This study aimed to evaluate the perception and degree of satisfaction of blind individuals regarding an electronic cane prototype with a wearable haptic interface.
METHODS: Two scenarios with different obstacles were created to conduct tests with the canes (the user's cane and the prototype one). The perception and satisfaction of participants regarding the electronic cane were assessed using a questionnaire, the number of collisions during the tests, and the time each individual took to complete the course in each scenario.
RESULTS: Ten blind individuals who used the white cane participated in this study. Eight were males, and two were females. Their age ranged from 23 to 43 (average 32.3 ± 7.13 years and median 32 years). There was a tendency for fewer collisions with ground obstacles when the electronic cane was used than when the white cane was used. However, there was no statistically significant difference between the number of collisions and the course completion time in each scenario with either canes tested.
CONCLUSION: Overall, the perception and satisfaction of individuals regarding the prototype used were positive.
Keywords: Blindness; Canes; Patient satisfaction; Perception; Haptic technology; Wearable electronic devices; Surveys and questionnaires
Abstract
OBJETIVO: Associar os resultados refrativos a longo prazo da cirurgia de catarata e a função visual autorreferida pelo questionário Catquest-9SF.
MÉTODOS: Paciente recrutados no ambulatório de catarata da VER MAIS Oftalmologia, foram submetidos a exame oftalmológico completo. Após diagnóstico de catarata com indicação de tratamento cirúrgico com facoemulsificação e implante de lente intraocular, o questionário foi aplicado antes da intervenção, 30 dias após cirurgia e 1 ano após, novamente.
RESULTADOS: Foram recrutados 133 pacientes. No decorrer do seguimento, 32 pacientes foram perdidos e ao final foram analisados os dados de 101 pacientes, dos quais 48 foram homens e 53 foram mulheres. A variância bruta explicada por dados foi de 69,9% e a inexplicada em primeiro contraste por 2,39 eigenvalores, sendo maior que 2, o que nos mostra que são resultados diferentes dos esperados de dados aleatórios. O índice de separação de pessoas foi de 2.95 (>2) e o valor de confiança de pessoas foi de 0,9 (>0,8). Estes índices são os valores mínimos aceitáveis na diferenciação de níveis de habilidade. Acuidade visual foi a principal variável correlacionada com o score do Catquest.
CONCLUSÕES: O Catquest-9SF traduzido para o português se demonstrou unidimensional e uma ferramenta psicometricamente válida para avaliar disfunção visual em pacientes com catarata, além de ter tido sucesso para quantificar objetivamente melhoras após a intervenção cirúrgica. Essa ferramenta pode ser utilizada como preditiva e concordante da melhora da acuidade visual.
Keywords: Extração de catarata; Acuidade visual; Inquéritos e questionários; Qualidade de vida; Medidas de resultados relatados pelo paciente
Abstract
PURPOSE: To evaluate the current scenario of rehabilitation services for people with retinal diseases in Brazil.
METHODS: An exploratory study was conducted between February 2023 and June 2023 using a Google Forms questionnaire that was distributed by patient associations.
RESULTS: A total of 142 patients, aged 18-80 were included in the study. Forty-eight participants (33.8%) were undergoing rehabilitation, while 94 (66.2%) were not. The main reason for not undergoing rehabilitation was a lack of knowledge about the service (n=41, 43.6%). Healthcare professionals made the most referrals (n=20, 41.7%). Rehabilitation improved the quality of life in 38 (80.9%) participants, and 28 (62.2%) participants were satisfied with the process. There was a statistically significant disparity between patient satisfaction and the locale of rehabilitation implementation. Twenty-three (69.7%) participants who underwent rehabilitation at a specialized center reported satisfaction.
CONCLUSION: The rehabilitation process directly increases the quality of life of individuals with retinal diseases. However, despite the availability of rehabilitation centers in large parts of Brazil, most patients with retinal diseases are not acquainted with the rehabilitation process and do not receive referrals for it. Thus, healthcare providers should increase referrals to rehabilitation centers, and public policies should be formulated to raise awareness among the population regarding the availability of rehabilitation services.
Keywords: Rehabilitation; Quality of life; Retinal diseases; Personal satisfaction; Patient care team; Public policy; Surveys and questionnaires; Brazil
Abstract
OBJETIVO: A deficiência visual e a cegueira causadas pela catarata são um grande problema de saúde pública. Há vários fatores associados a um risco maior de catarata relacionada à idade na população mundial, tais como idade, tabagismo, consumo de álcool e radiação ultravioleta. Esta meta-análise foi realizada para avaliar a associação entre o índice de massa corporal e a catarata relacionada à idade.
MÉTODOS: Foi revisada a literatura sobre catarata relacionada a peso e idade publicada de janeiro de 2011 a julho de 2020, através de buscas nos bancos de dados PubMed, Medline e Web of Science. Na meta-análise, foram utilizados modelos de efeito aleatórios e de efeitos fixos e os resultados foram apresentados como razões de chances (OR).
RESULTADOS: Um total de 9 estudos foi incluído na meta-análise. Não houve correlação entre ausência de sobrepeso e cataratas nucleares (OR=1,31, IC 95%: −0,50-3,12, p=0,156). Os resultados do modelo de efeitos aleatórios mostraram que o excesso de peso estava significativamente associado a uma redução do risco de catarata relacionada à idade (OR=0,91, IC 95%: 0,80-1,02, p<0,0001, I2=62,3%, p<0,0001). Houve correlações significativas entre o excesso de peso e cataratas corticais (OR=0,95, IC 95%: 0,66-1,24, p<0,0001), nucleares (OR=0,92, IC 95%: 0,76-1,08, p<0,0001) e subcapsulares posteriores (OR=0,87, IC 95%: 0,38-1,02, p<0,0001) relacionadas à idade. Houve correlações significativas entre obesidade e cataratas corticais (OR=1,00, IC 95%: 0,82-1,17, p<0,0001), nucleares (OR=1,07, IC 95%: 0,92-1,22, p<0,0001) e subcapsulares posteriores (OR=1,14, IC 95%: 0,91-1,37, p<0,0001) relacionadas à idade.
CONCLUSÃO: Estes achados sugeriram uma correlação significativa entre o índice de massa corporal e a catarata relacionada à idade, com o excesso de peso e a obesidade reduzindo e aumentando o risco de catarata relacionada à idade, respectivamente.
Keywords: Envelhecimento; Catarata; Índice de massa corporal; Sobrepeso; Obesidade
Abstract
Objetivos: Avaliar a segurança e eficácia a longo prazo da vitreólise com Nd:YAG laser para moscas volantes sintomáticas, uma vez que permanece como um procedimento controverso devido a falta de evidência científica robusta sobre a manutenção dos resultados e ocorrência de efeitos adversos.
Métodos: Este estudo é uma extensão observacional de um ensaio clínico prospectivo, randomizado, duplo cego, previamente publicado. Oito de treze pacientes que foram submetidos a vitreólise com YAG laser foram acompanhados para uma reavaliação tardia, dezoito meses após o procedimento, para avaliar a eficácia e segurança do procedimento.
Resultados: Todos os pacientes mantiveram a melhora na sintomatologia notada ao final do procedimento original, com 25% dos casos apresentando melhora completa, e uma proporção semelhante (37,5%) demonstrando melhora significativa ou parcial. A melhora objetiva na opacidade foi similar ao achado no seguimento original de 6 meses. O questionário de qualidade de vida NEI-VFQ 25 não demonstrou diferença estatisticamente significativa nas respostas entre o sexto e o décimo oitavo mês de acompanhamento. Nenhum efeito adverso foi notado no exame clínico ou reportado pelos pacientes.
Conclusão: A eficácia da vitreólise observada ao sexto mês do acompanhamento foi mantida até o décimo oitavo mês, com todos os pacientes notando algum grau de melhora quando comparado ao estado pré procedimento. Nenhum efeito adverso tardio foi notado. Um ensaio clínico randomizado maior é necessário para confirmar a segurança do procedimento.
Keywords: Terapia a laser; Lasers de estado sólido; Vitrectomia; Corpo vítreo; Cirurgia vitreorretiniana; Acuidade visual; Doenças oculares; Qualidade de vida; Inquéritos e questionários
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Arquivos Brasileiros de Oftalmologia
Official publication of Brazilian Council of Ophthalmology - Conselho Brasileiro de Oftalmologia (CBO)
Rua Casa do Ator, 1.117 - 2nd floor - Zip Code: 04546-004
São Paulo - SP, Brazil
TEL: +55 11 3266-4000
E-mail: [email protected]