Abstract
Objetivo: Fornecer informações sobre a ocorrência e a eficácia do aconselhamento sobre o uso de tabaco por oftalmologistas a pacientes com doenças oculares associadas à tireoide.
Métodos: Analisamos os prontuários médicos eletrônicos de uma coorte digital de pacientes atendidos por oftalmologistas no Sistema de Saúde da Universidade da Pensilvânia entre o início de 2012 e o final de 2017 com os códigos da Classificação Internacional de Doenças (CID) para a doença de Graves, exoftalmia tireotóxica ou doença ocular associada à tireoide. Os históricos de uso de tabaco foram registrados na primeira e na última visita ao consultório de Oftalmologia, ou na visita mais próxima no tempo. A quantidade de maços/dia (mpd) e todas as anotações feitas nas visitas ao consultório de Oftalmologia foram analisadas para aconselhamento sobre o uso de tabaco.
Resultados: Um total de 435 indivíduos preencheram os critérios de inclusão, dos quais 72 (16,6%) estavam fumando ativamente no momento do primeiro encontro. Apenas 57 (79,2%) desses indivíduos que fumam ativamente registraram queixas relacionadas ao tabagismo, sendo que 34 (59,6%) deles receberam alguma forma de aconselhamento sobre o uso de tabaco. Ao todo, 9 (26,5%) indivíduos dentre os que receberam aconselhamento sobre tabaco e 1 (4,3%) que não teve aconselhamento registrado pararam de fumar (diferença de risco de 22,1%; IC 95%, [1,7%, 39,1%]; p=0,04). Dentre aqueles que receberam aconselhamento, 17 (50,0%) reduziram seus mpd, além de 7 (30,4%) daqueles que não tiveram aconselhamento (diferença de risco de 19,6%; IC 95% [-6,3%, 41,3%]; p=0,18). No geral, 14 (25,5%) dos 55 oftalmologistas que tiveram um paciente fumante ativo registraram evidências de aconselhamento sobre o uso de tabaco.
Conclusões: Os resultados deste estudo revelam tanto as oportunidades perdidas de aconselhamento sobre o uso do tabaco quanto a eficácia do aconselhamento no contexto de doenças oculares associadas à tireoide.
Keywords: Uso de tabaco; Aconselhamento; Doenças da glândula tireóide; Doença de Graves; Oftalmopatias
Abstract
Objetivo: Avaliar a superfície ocular e a morfologia da glândula meibomiana em usuários de cigarros eletrônicos.
Métodos: Foram avaliadas através de meibografia Sirius as pálpebras superiores e inferiores de 25 usuários de cigarros eletrônicos do sexo masculino e 25 pacientes não usuários saudáveis, também do sexo masculino. A perda nas glândulas meibomianas foi calculada automaticamente com o módulo de software de imagem de meibografia Phoenix. O resultado foi obtido como perda percentual. O questionário Ocular Surface Disease Index (OSDI), o teste do tempo de ruptura lacrimal e o teste de Schirmer II foram administrados em todos os casos.
Resultados: A duração média do uso de cigarros eletrônicos foi de 4,9 ± 0,9 anos (intervalo de 3,4-7 anos). O valor médio do teste de Schirmer II foi de 9,16 ± 2,09 mm no grupo de usuários de cigarros eletrônicos e de 11,20 ± 2,14 mm no grupo controle (p=0,003). O valor médio do teste do tempo de ruptura lacrimal foi de 6,96 ± 2,31 segundos no grupo de usuários de cigarros eletrônicos e 9,84 ± 2,13 segundos no grupo controle (p=0,002). O valor médio do Ocular Surface Disease Index foi de 28,60 ± 6,54 e 15,16 ± 7,23 para os grupos de usuários de cigarros eletrônicos e controle, respectivamente (p<0,001). Na meibografia de Sirius, a perda média para a pálpebra superior foi de 23,08 ± 6,55% para o grupo de usuários de cigarros eletrônicos e 17,60 ± 4,94% para o grupo controle (p=0,002), e a perda média para a pálpebra inferior foi de 27,84 ± 5,98% e 18,44 ± 5,91%, respectivamente (p<0,001). Além disso, foi observada uma correlação positiva significativa entre a taxa de perda na meibografia palpebral superior e inferior com a duração do tabagismo eletrônico, respectivamente de (r=0,348, p<0,013) e (r=0,550, p<0,001).
Conclusão: O uso prolongado de cigarros eletrônicos causa danos às glândulas meibomianas. Portanto, esses danos devem ser considerados em distúrbios da superfície ocular devidos ao uso desses dispositivos.
Keywords: Sistemas eletrônicos de liberação de nicotina; Glândulas tarsais; Disfunção da glândula tarsal/diagnostico; Fumar/efeitos adversos; Vaping/efeitos adversos; Técnicas de diagnóstico oftalmológico.
Abstract
Objetivo: O objetivo deste estudo é investigar os efeitos dos antidepressivos tricíclicos, dos inibidores da recaptação da serotonina e dos inibidores da recaptação da serotonina e noradrenalina na superfície ocular.
Métodos: Foram incluídos no estudo 330 olhos de 165 pacientes em uso de antidepressivos e 202 olhos de 101 controles. Foi medido o tempo de ruptura do fluido lacrimal e foram administrados o teste de Schirmer I e o questionário Ocular Surface Disease Index (OSDI). Os Inventários de Depressão e de Ansiedade de Beck foram aplicados ao uso dos medicamentos e foram registrados as dosagens, a duração da doença psiquiátrica e o tempo de remissão.
Resultados: No grupo de estudo, o tempo médio de ruptura do fluido lacrimal foi de 14,29 ± 4,81 segundos (intervalo de 4-26 segundos) e o valor médio do teste de Schirmer I foi de 16,05 ± 5,89 mm (intervalo de 2-28 mm). No grupo controle. o tempo médio de rompimento do fluido lacrimal foi de 18,16 ± 2,12 segundos (intervalo de 15-24 segundos) e o valor do teste de Schirmer I foi de 16,64 ± 2,31 mm (intervalo de 15-24 mm), com p<0,001 e p=0,005, respectivamente. No grupo de estudo, 38,18% (n=63) dos pacientes tinham olho seco, enquanto no grupo controle 17% (n=18) tinham olho seco (p<0,001). O escore médio no OSDI foi de 82,56 ± 16,21 (intervalo 66-100) no grupo dos antidepressivos tricíclicos, 60,02 ± 29,18 (10-100) no grupo dos inibidores da recaptação da serotonina e 22,30 ± 20,87 (0-75) no grupo dos inibidores da recaptação da serotonina e noradrenalina (p<0,001). O tempo médio de rompimento do fluido lacrimal foi de 14,36 ± 3,35 segundos (intervalo de 10-20 segundos) no grupo dos antidepressivos tricíclicos, 13,94 ± 5,81 segundos (intervalo de 4-26 segundos) no grupo dos inibidores da recaptação de serotonina e 14,93 ± 4,20 segundos (intervalo de 6-20 segundos) no grupo dos inibidores da recaptação de serotonina e noradrenalina (p=0,730). O valor médio do teste de Schirmer I foi de 9,90 ± 7,22 mm (intervalo de 2-30 mm) no grupo dos antidepressivos tricíclicos, 15,55 ± 5,15 mm (intervalo de 2-25 mm) no grupo dos inibidores da recaptação da serotonina e 17,71 ± 4,21 mm (intervalo de 10-30 mm) no grupo dos inibidores da recaptação da serotonina e noradrenalina (p<0,001). Não houve diferença estatisticamente significativa no escore OSDI, no tempo de ruptura do fluido lacrimal e nos valores do teste de Schirmer I entre os subgrupos de pacientes em uso de inibidores da recaptação de serotonina e de inibidores da recaptação de serotonina e noradrenalina.
Conclusões: Olho seco é uma queixa comum em usuários de antidepressivos, mas no que diz respeito à superfície ocular, inibidores da recaptação de serotonina e noradrenalina podem ser mais confiáveis que outros antidepressivos. Pacientes em uso de inibidores da recaptação de serotonina e noradrenalina têm escores menores no questionário OSDI. Os inibidores da recaptação da serotonina e noradrenalina, úteis nas síndromes de dor crônica, também podem ter um efeito corretivo nos sintomas de olho seco.
Keywords: Inibidores de recaptação de serotonina; Antidepressivos tricíclicos; Serotonina; Depressão; Dor crônica; Síndromes do olho seco; Norepinefrina; Inquéritos e questionários; Ansiedade; Preparações farmacêuticas.
Abstract
PURPOSE: To assess the reliability and penetration depth of an automated micropuncture system using a tattoo machine.
METHODS: Twenty human corneas were obtained and subjected to intrastromal micropuncture using a tattoo machine. Each cornea was divided into two halves: one received pigment, while the other received saline solution as a control. The Cheyenne tattoo machine was operated at 60 Hz, with standardized needle exposure (six passes per application). The machine used cartridges containing five microneedles. The study was registered with Agência Nacional de Vigilância Sanitária ANVISA (numbers 80281110015, 80281110016, and 80281110019). The pigment used was Electric Ink black ink, with a density of 1,271,460 μg/mL. Puncture depth was measured before and after the procedure using both anterior segment optical coherence tomography and histopathological analysis. Puncture depth measurements were analyzed using ImageJ software. Each cornea was measured thrice, and the results were subsequently compared.
RESULTS: No corneal perforations were observed with the use of the tattoo machine, and puncture depth measurements ranged from 107 to 486 µm.
CONCLUSIONS: The use of a tattoo machine represents a viable and accessible approach for keratopigmentation, with potential for both cosmetic and therapeutic applications. Its adaptation for controlled intrastromal drug delivery may enable the targeted treatment of deep infectious keratitis, corneal neovascularization, and stromal inflammatory disorders, representing a promising approach for corneal stromal diseases. Further research is needed to optimize techniques and evaluate long-term safety and efficacy, particularly for the delivery of antimicrobial, anti-inflammatory, and anti-vascular endothelial growth factor agents.
Keywords: Eye banks; Cadaver; Cornea; Corneal stroma; Drug delivery systems; Tissue donors; Tattooing/instrumentation; Punctures
Abstract
Objetivos: O objetivo do estudo é avaliar o perfil das visitas ao Pronto-Socorro de Oftalmologia (PS) do Hospital São Paulo, serviço público de atendimento terciário aberto 24 horas em São Paulo - Brasil, pertencente à Universidade Federal de São Paulo, nos últimos 11 anos.
Métodos: Foi realizado um estudo transversal retrospectivo, com base em todos os pacientes (n=634.726) admitidos no pronto-socorro de oftalmologia do Hospital São Paulo entre janeiro de 2009 e dezembro de 2019.
Resultados: De 2009 a 2019, houve um aumento no influxo de 39,2% com importante variação nos atendimentos ao longo dos anos, a mediana de idade foi de 38 ± 20,4 anos, o sexo masculino representou 53,3% e os pacientes únicos representaram 53,1%. Verificou-se que 79,5% das visitas ocorreram das 7h às 17h e 80,8% nos dias da semana. Os diagnósticos mais frequentes foram conjuntivite aguda seguida de blefarite, ceratite, hordéolo / calázio e corpo estranho corneano.
Conclusão: Ao longo do período de análise do estudo, houve importante aumento nas apresentações, com predominância de atendimentos não urgentes e baixa proporção de pacientes com uma única visita. Nossos resultados evidenciam o perfil das consultas oftalmológicas, podendo gerar mudanças no sistema público de saúde visando a melhoria da qualidade do atendimento e acesso às emergências oftalmológicas na cidade de São Paulo.
Keywords: Serviço hospitalar de emergência; Epidemiologia; Traumatismos oculares; Oftalmopatias.
Abstract
Objetivo: Este estudo de qualidade e confiabilidade teve como objetivo identificar a variabilidade da massa do volume da gota de colírios multidose e verificar a existência de um padrão de referência para o volume da gota dos colírios usando lágrimas artificiais do mercado brasileiro.
Métodos: Cinco marcas de colírios lubrificantes foram avaliadas quanto ao volume da gota. Uma gota padrão ideal de 20 μL de cada fabricante foi coletada usando uma micropipeta ajustável. Os frascos dos colírios foram selecionados aleatoriamente e cinco medidas das massas das amostras foram coletadas usando escalas de precisão calibradas.
Resultados: A massa das amostras de 20 μL variou significativamente (p<0,001) entre os diferentes fabricantes. No entanto, entre os colírios da mesma marca, a variação da massa não foi estatisticamente diferente. A massa média global de todas as gotas pesadas foi de 18,24 mg e foi observada uma não-uniformidade entre todas as marcas de colírios.
Conclusão: Identificou-se uma variação significativa nas massas do volume das gotas dos colírios lubrificantes, usando equipamento padrão de laboratório. A heterogeneidade no volume da gota dos colírios testados sugere a existência de discrepâncias potenciais em suas posologias, possivelmente alterando a eficácia do tratamento. Uma medida de referência pré-estabelecida pode levar à produção de colírios com gotas de tamanho mais apropriado para uso em olhos humanos.
Keywords: Soluções oftálmicas/administração & dosagem; Volume da gota; Padrão de referência dos colírios; Padronização de colírios multidose; Administração de medicamentos oftálmicos; Qualidade
Abstract
PURPOSE: This study aimed to determine whether early-stage intraocular pressure can be modulated using a thermal face mask.
METHODS:In this prospective clinical study, healthy participants were randomized on a 1:1:1 allocation ratio to three mask groups: hypothermic (G1), normothermic (G2), and hyperthermic (G3). After randomization, 108 eyes from 108 participants were submitted to clinical evaluations, including measurement of initial intraocular pressure (T1). The thermal mask was then applied for 10 minutes, followed by a second evaluation of intraocular pressure (T2) and assessment of any side effects.
RESULTS:The hypothermic group (G1) showed a significant reduction in mean intraocular pressure between T1 (16.97 ± 2.59 mmHg) and T2 (14.97 ± 2.44 mmHg) (p<0.001). G2 showed no significant pressure difference between T1 (16.50 ± 2.55 mmHg) and T2 (17.00 ± 2.29 mmHg) (p=0.054). G3 showed a significant increase in pressure from T1 (16.53 ± 2.69 mmHg) to T2 (18.58 ± 2.95 mmHg) (p<0.001). At T1, there was no difference between the three study groups (p=0.823), but at T2, the mean values of G3 were significantly higher than those of G1 and G2 (p<0.00).
CONCLUSION:Temperature was shown to significantly modify intraocular pressure. Thermal masks allow the application of temperature in a controlled, reproducible manner. Further studies are needed to assess the duration of these effects and whether they are reproducible in patients with pathologies that affect intraocular pressure.
Keywords: Intraocular pressure; Temperature; Masks; Glaucoma; Eye diseases
Abstract
PURPOSE: Access to cataract treatment and diagnostic tools continues to be hindered by financial and logistical barriers. Thus, photography-based cataract analysis via portable devices offers a promising solution for the detection of cataracts in remote regions. In this study, the accuracy of a portable device that is based on the Lens Opacities Classification III System for diagnosing cataracts was analyzed.
METHODS: Photographs of the anterior segment of the eye were taken in a low-light environment, and the pupillary region markings were automatically delineated using infrared photography. The captured images were automatically analyzed using a convolutional neural network. The study group included patients with cataracts, and the control group included patients without cataracts.
RESULTS:A total of 270 eyes were analyzed, which included 143 eyes with cataracts and 127 control eyes. A total of 599 photos were analyzed. The isolated nuclear cataract was the most frequently detected subtype (37.5%), followed by a nuclear cataract associated with a cortical cataract (30.3%). The device's accuracy was 88.5% (Confidence intervals (CI), 83.19%–94.69%), specificity was 84.62% (CI 71.79%–97.30%), positive predictive value was 91.78% (CI 74.36%–97.30%), and negative predictive value was 82.50% (CI 74.36%–97.30%).
CONCLUSION: The portable device is a simplified user-friendly cataract screening technique that can interpret results in remote regions. This innovation could mitigate the occurrence of cataract-induced blindness and prevent premature surgical interventions in early-stage cataracts.
Keywords: Cataract/diagnosis; Diagnostic techniques ophthalmological/instrumentation; Optical devices; Equipment and supplies; Eye-tracking technology
Abstract
PURPOSE: To evaluate the effects of a propylene glycol–hydroxypropyl guar nanoemulsion on symptoms and ocular surface parameters in patients with evaporative dry eye.
METHODS: This prospective, single-center, interventional study included patients aged 18–50 years with evaporative dry eye who received a propylene glycol–hydroxypropyl guar nanoemulsion. Participants were instructed to instill the nanoemulsion three times daily for 90 days. Evaluations included the Ocular Surface Disease Index, tear osmolarity, tear meniscus height, lipid layer thickness, noninvasive tear break-up time, fluorescein tear break-up time, corneal fluorescein staining (National Eye Institute Scale), Schirmer’s test I, and meibum quality.
RESULTS: Thirty-three participants were enrolled, and 30 completed the study. The mean age was 36 ± 10 yr, and 73.3% were women. The mean Ocular Surface Disease Index score significantly decreased from 43.1 ± 20 at baseline to 25.2 ± 17 at 3 months (p=0.009). Median corneal fluorescein staining decreased from 2 (IQ range=1–3) to 1 (IQ range 25–75 = 0–1) at the final follow-up (p=0.002). The mean fluorescein tear break-up time increased significantly increased from 3.8 ± 2.1 at baseline to 5.8 ± 2.2 at 3 months (p=0.002). Tear osmolarity decreased significantly (p=0.01) and lipid layer thickness improved markedly (p<0.001). No significant changes were observed in tear meniscus height or noninvasive tear break-up time (p>0.05).
CONCLUSIONS: Treatment with a propylene glycol–hydroxypropyl guar nanoemulsion significantly improved dry-eye symptoms, corneal staining, tear film stability, and lipid layer quality in patients with evaporative dry eye. No adverse events were reported, supporting the safety and efficacy of this formulation.
Keywords: Dry eye syndromes/drug therapy; Meibomian gand dysfunction/drug Dry Eye therapy; Tears; Emulsions; Lubricant eye drops; Nanoparticles; Propylene glycol/therapeutic use; Polysaccharides/ therapeutic use
Abstract
OBJETIVO: Analisar a teleconsulta em um hospital público de ensino oftalmológico, durante o período da pandemia do COVID-19.
MÉTODOS: Foram revisados os registros médicos dos pacientes que solicitaram teleconsulta oftalmológica, no período de Junho de 2020 a Março de 2021. Os resultados incluem dados demográficos, sintomas de queixas oculares e hipóteses diagnósticas. Além disso, foram analisados dados da pesquisa de satisfação aplicada após cada teleconsulta.
RESULTADOS: Um total de 161 prontuários foram revisados. A idade média dos pacientes foi de 45.98 ± 17.57 (8 a 90) anos, a maioria mulheres, 113 (70,20%). Apenas 57 (35,60%) eram pacientes acompanhados no hospital previamente. A principal razão pela busca pela teleconsulta foi o erro refracional, 73 (45.43%), seguido de olho seco, 16 (9.93%), pterígio, 13 (8.07%). Outros motivos foram o acompanhamento de doenças prévias como glaucoma, retinopatias, miopia, estrabismo e ceratocone. Quanto a pesquisa de satisfação, 151(93,87%) pacientes responderam a pesquisa on-line. A maioria deles mostrou-se satisfeito com a teleconsulta (94.03%) e fariam uma nova teleconsulta (90.06%).
CONCLUSÃO: A teleconsulta pode auxiliar a saúde pública em oftalmologia podendo ser utilizada em hospitais universitários. Embora o erro refracional tenha sido o motivo mais frequente nas consultas, os pacientes mostraram-se satisfeitos com essa modalidade de atendimento que serve como um serviço de orientação.
Keywords: COVID-19; Telemedicina; Pandemias; Consulta remota; Oftalmopatias/diagnóstico; Hospitais públicos
Abstract
PURPOSE: To compare objective and subjective intraocular pressure measurements immediately after cataract surgery and intraocular pressure measurements between less experienced surgeons (Group 1) and experienced surgeons (Group 2).
METHODS: Surgeons were asked to estimate the IOP after corneal sealing after surgery based on their tactile perception of eye tension (subjective intraocular pressure) Objective intraocular pressure was measured using a Perkins tonometer while patients were still in the surgical field. Objective intraocular pressure was compared to subjective intraocular pressure. Results from less experienced surgeons were compared to more experienced surgeons.
RESULTS: The study comprised 81 surgeries (81 eyes) performed by 27 surgeons. The mean objective intraocular pressure (9.14 mmHg; SD=5.86) was statistically significantly lower (p<0.001) than the mean subjective intraocular pressure (19.21 mmHg; SD=4.82). Hypotony (intraocular pressure <6mmHg) was observed in 25 eyes (30.86%). The mean subjective intraocular pressure was 18.8 mmHg (SD=5.19) for less experienced surgeons and 19.5 mmHg (SD=4.46) for more experienced, without statistically significant difference (p=0.541). No statistically significant difference (p=0.71) was observed when comparing objective intraocular pressure in Group 1 (10.32 mmHg; SD=6.65) and Group 2 (7.97 mmHg; SD=4.7).
CONCLUSION: Objective intraocular pressure was significantly lower than subjective intraocular pressure, regardless of surgeons' experience. This study showed that the subjective method is unreliable compared to the gold standard (Perkins tonometer) and does not improve with surgeons' experience. Establishing standard training methods is paramount to developing surgeons' skills.
Keywords: Cataract; Intraocular pressure; Hypotony, Tonometry; Eye diseases; Training
Abstract
OBJETIVO: Comparar os resultados de 3 meses de soro autólogo a 20% com um tratamento combinado, ou seja, lubrificantes oculares sem conservantes e ciclosporina a 0,05% em pacientes com síndrome do olho seco devida à síndrome de Sjögren primária.
MÉTODOS: Foram incluídos no estudo 130 olhos de 65 pacientes recentemente diagnosticados com síndrome do olho seco devida à síndrome de Sjögren primária. Os pacientes foram divididos em dois grupos de tratamento, 66 olhos de 33 pacientes foram incluídos no grupo de tratamento com soro autólogo e 64 olhos de 32 pacientes foram incluídos no grupo de tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina. Os resultados do teste de Schirmer e do tempo de ruptura do filme lacrimal e os índices de doença da superfície ocular (OSDI) foram registrados antes e depois de três meses de tratamento.
RESULTADOS: Três meses após o tratamento, o valor médio do teste de Schirmer foi mais alto com significância estatística no grupo do tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina (p<0,0001) e o tempo de ruptura do filme lacrimal também foi significativamente maior nesse grupo (p=0,034). Também aos três meses, a doença da superfície ocular foi menor com significância estatística no grupo de tratamento com soro autólogo (p=0,004). Quando os dois grupos foram avaliados separadamente, a melhora no teste de Schirmer, o tempo de ruptura e a doença da superfície ocular antes e depois do tratamento tiveram diferenças estatisticamente significativas tanto no grupo de soro autólogo (p<0,0001, p<0,001 e p<0,0001, respectivamente) quanto no grupo de tratamento combinado (p<0,0001, p<0,001 e p<0,0001, respectivamente).
CONCLUSÕES: No tratamento de curto prazo da síndrome do olho seco devida à síndrome de Sjögren primária, o tratamento com soro autólogo foi significativamente superior ao tratamento com lubrificantes oculares sem conservantes combinados com ciclosporina, em termos de melhora no doença da superfície ocular. As melhoras no teste de Schirmer e no tempo de ruptura do filme lacrimal foram significativamente maiores no grupo de tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina.
Keywords: Síndrome de Sjögren/complicações; Síndrome do olho seco/etiologia; Síndrome do olho seco/tratamento farmacológico; Ciclosporina/uso terapêutico; Lubrificantes oftalmológicos
Abstract
The paper starts discussing the teleological concept that eye motions - rotations and translations - serve to vision (which supports the notion that torsions are not voluntarily driven, since they do not contribute to expand the visual exploration of space). It proposes that the primary position of the eye (not "of gaze") , the standard condition to measure them, must be defined as the coincidence of the orbital (fixed) and the ocular (movable) system of coordinates. However this becomes only a theoretic concept, since practical operations to obtain it are almost unfeasible. Besides, even a "simple" horizontal or vertical ocular rotation, though always occurring around a (presumably) fixed point (the center of ocular rotation) may be defined by different trajectories and magnitudes, depending on the two systems of measurement of eye positions and motions. Hence, in a graphical (plane) representation of such spherical coordinates, the so-called "tangent screen", an ocular "tertiary" position - a combination of a horizontal and a vertical rotations - may be described by four different points. Or, conversely, a specific eye position may be defined by four sets of angular coordinates. The mathematical representation of variation of three special coordinates in a specific rotation is best made by a matrix disposition, so that, multiplication (not commutative) of three matrices (one for each specific plane) generates six different systems (permutations) of measurements. So, though , actually, there are multiple trajectories possible between two points in space, the order in which rotations are considered influences the final result. With different systems of coordinates for each rotation and different possible orders by which they may be considered, one reaches 48 alternative systems for their measurements. Unfortunately, up to now, there I is no an established convention to express ocular rotations. So, usually, people consider that a vertical prism superimposed to a frontally placed horizontal prism, or vice-versa, correspond to equivalent processes. The paper finishes discussing inconveniences of the clinically used unity to measure eye rotations (the prism-diopter) and proposes other unities as alternative solutions.
Keywords: Angular measurement unity; eye movements; eye position measurement; eye position measurement accuracy; Fick's system; Helmholtz's system; ocular rotation; primary position of gaze; prism-diopter referential systems; superimposition of prisms
Abstract
Bilateral acute depigmentation of the iris and bilateral acute iris transillumination (BAIT) are similar clinical entities. The former causes acute-onset depigmentation of the iris stroma without transillumination, whereas the latter causes depigmentation of the iris pigment epithelium with transillumination. The etiopathogenesis of these conditions is not yet fully understood, but the proposed causes include the use of systemic antibiotics (especially moxifloxacin) and viral triggers. We present a case series of five female patients with a mean age of 41 (32-45) years, all of whom suffered acute onset of bilateral pain and redness of the eyes after moxifloxacin use (oral or topical). It is important for ophthalmologists to be aware of the two forms of iris depigmentation since this case series suggests that SARS-CoV-2 or its empirical treatment with moxifloxacin may trigger iris depigmentation. If this is the case, clinicians will likely see increased incidences of bilateral acute depigmentation of the iris and bilateral acute iris transillumination during and after the COVID-19 pandemic.
Keywords: SARS-CoV-2; Pigment epithelium of eye; Iris diseases/pathology; Transillumination; Ocular hypertension; Intraocular pressure; Drug related side effect and adverse reactions; Iris diseases/drug therapy; Moxifloxacin/therapeutic Use; Humans; Case reports
Abstract
Langerhans cell histiocytosis comprises a heterogeneous range of clinical manifestations secondary to clonal proliferation of histiocytes, characterized by the accumulation of these cells in various organs and tissues. The ophthalmological component commonly involved is the orbit. Herein, we report a rare case of Langerhans cell histiocytosis with eyelid involvement, which resulted in severe ocular surface complications, which subsequently significantly impacted the patient's quality of life. This case report highlights the fact that despite being rare, Langerhans cell histiocytosis should be included in the differential diagnosis of eyelid lesions. Furthermore, a multidisciplinary approach with a systemic overview is crucial for managing the ocular complications.
Keywords: Dry eye syndromes; Erdheim-Chester disease/drug therapy; Human; Female; Case reports