Abstract
Objetivo: O objetivo deste estudo é comparar as medições de diâmetro corneano de dois dispositivos normalmente utilizados na prática clínica (IOL Master 500 e Atlas topógrafo corneal) para ver se são permutáveis. O fornecimento de informações sobre a permutabilidade de instrumentos poderia eliminar vários testes desnecessários e, consequentemente, reduzir a carga econômica para o paciente e para a sociedade.
Métodos: Nesta série de casos prospectivos e comparativos, a distância do diâmetro corneano foi medida por examinadores independentes utilizando o Topógrafo Atlas (Carl Zeiss Meditec) e o IOL Master 500 (Carl Zeiss Meditec), em um olho de 184 pacientes. A análise estatística foi realizada utilizando o teste t pareado, a correlação Pearson e a análise Bland-Altman para comparar os métodos de medição.
Resultados: As medições médias da distância do diâmetro corneano com o topógrafo Atlas e o IOL Master 500 foram de 12,20 ± 0,44 mm e 12,12 ± 0,41 mm, respectivamente (p<0,001). A diferença média de WTW entre os dois dispositivos foi de 0,07 mm (intervalo de confiança de 95% da diferença média: 0,04 - 0,11 mm). O coeficiente de correlação Pearson entre os dois dispositivos foi de 0,85, p<0,0001. Os limites de concordância de 95% entre os dois dispositivos foram de -0,38 mm a 0,53 mm.
Conclusões: O Atlas topographer e o IOL Master 500 podem ser utilizados permutavelmente em relação à medição do diâmetro corneano, uma vez que a gama de diferenças encontradas é pouco susceptível de afetar a prática clínica e a tomada de decisões.
Keywords: Topografia da córnea; Comprimento axial do olho; Técnicas de diagnóstico oftalmológico; Procedimentos cirúrgicos oftalmológicos.
Abstract
Objetivo: Este estudo teve como objetivo comparar os resultados clínicos após ceratoplastia lamelar anterior profunda e ceratoplastia penetrante nos olhos contralaterais dos mesmos pacientes.
Métodos: Nesta série de casos comparativa e retrospectiva, avaliaram-se os seguintes dados de resultados clínicos: melhor acuidade visual corrigida, equivalente esférico refrativo, astigmatismo refrativo, densidade de células endoteliais, perda de células endoteliais, espessura central da córnea e pressão intraocular. Esses dados foram avaliados aos 6, 12, 24 e 36 meses após ceratoplastia lamelar anterior profunda e ceratoplastia penetrante. Também foram avaliadas as complicações.
Resultados: Foram incluídos 52 olhos (26 pacientes), sendo que 19 pacientes apresentavam ceratocone, 6 apresentavam distrofia estromal e 1 apresentava ectasia após ceratomileuse in situ assistida por laser. O tempo médio de acompanhamento foi de 44,1 ± 10,5 meses no grupo da ceratoplastia lamelar anterior profunda e 47,9 ± 11,9 meses no grupo da ceratoplastia penetrante. Nenhuma diferença significativa foi observada nas médias da melhor acuidade visual corrigida, equivalente esférico refrativo, astigmatismo refrativo e espessura central da córnea entre os grupos da ceratoplastia lamelar anterior profunda e da ceratoplastia penetrante durante o acompanhamento. A densidade de células endoteliais foi significativamente maior no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante aos 24 e 36 meses de pós-operatório (p=0,022 e 0,013, respectivamente). A perda de células endoteliais foi significativamente menor no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante aos 24 e 36 meses de pós-operatório (p=0,025 e 0,001, respectivamente). A pressão intraocular foi significativamente menor no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante aos 6 meses de pós-operatório (p=0,015). Ocorreu microperfuração em 4 olhos (15%) durante a cirurgia de ceratoplastia lamelar anterior profunda; entretanto, a ceratoplastia penetrante não foi necessária. Não ocorreu nenhuma rejeição endotelial no grupo da ceratoplastia penetrante durante o período de acompanhamento.
Conclusões: Durante o acompanhamento de 3 anos, a perda de células endoteliais e a pressão intraocular foram significativamente menores no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante, mas os resultados visuais e refrativos foram semelhantes.
Keywords: Doenças da córnea/cirurgia; Ceratocone/cirurgia; Ceratoplastia penetrante/métodos; Transplante de córnea/métodos; Pressão intraocular; Estudo comparativo.
Abstract
Objetivo: Investigar a superfície ocular e as glândulas meibomianas em pacientes com acne vulgar não tratada.
Métodos: Todos os indivíduos responderam ao questionário Ocular Surface Disease Index (OSDI) e tiveram avaliados o tempo de ruptura do filme lacrimal pelo método invasivo, a coloração da superfície ocular com fluoresceína e o teste de Schirmer II. Foram ainda avaliados o escore palpebral total e o de secreção das glândulas meibomianas. Foi realizada meibografia sem contato com um dispositivo topográfico corneano Sirius.
Resultados: Foram incluídos no estudo os olhos direitos de 35 voluntários com acne vulgar e 35 saudáveis. Os escores do Ocular Surface Disease Index e da coloração foram significativamente maiores no grupo com acne em comparação com o grupo controle (p=0,01 e p=0,003, respectivamente), mas o tempo de ruptura do filme lacrimal pelo método invasivo e as medidas do teste de Schirmer II foram significativamente menores (p=0,000 e p=0,003, respectivamente). O escore palpebral total e o escore de secreção das glândulas meibomianas também foram maiores no grupo com acne que no grupo controle (p=0,003 e p=0,000). Na avaliação morfológica das glândulas meibomianas, o espessamento, o afinamento, a tortuosidade e a presença de áreas fantasmas nas glândulas foram mais comuns no grupo acne vulgar que no grupo controle, com significância estatística (p=0,000, p=0,001, p=0,05 e p=0,006 respectivamente). A porcentagem da área de perdas das glândulas meibomianas foi significativamente mais alta no grupo com acne vulgar, tanto na meibografia superior quanto na inferior. A área de perda das glândulas meibomianas demonstrou uma correlação positiva com o escore palpebral total e com o escore de secreção das glândulas meibomianas.
Conclusão: A acne vulgar pode levar a uma predisposição para a disfunção das glândulas meibomianas e para danos na superfície ocular. Parece ser importante reconhecer precocemente as alterações das glândulas meibomianas e da superfície ocular, especialmente nos casos de acne vulgar para os quais se planeja o tratamento oral com isotretinoína.
Keywords: Acne vulgar/complicação; Acne vulgaris/tratamento farmacológico; Isotretinoína/uso terapêutico; Pálpebra; Túnica conjuntiva/patologia; Síndrome do olho seco; Glândula tarsal; Técnica de diagnóstico oftalmológico; Questionário
Abstract
Objetivos: Avaliar o alívio de sintomas e sinais relacionados à secura ocular e na qualidade de vida de pacientes com síndrome de Sjögren tratados com o uso oral de pilocarpina na dose diária de 20mg. A frequência dos efeitos colaterais relatados com o tratamento também foi estudada.
Métodos: Trata-se de estudo cruzado e placebo-controlado, que envolveu 32 pacientes com síndrome de Sjögren em uso de pilocarpina oral ou placebo, por dez semanas. Após duas semanas sem medicações, houve a inversão dos tratamentos para cada paciente, por mais dez semanas. As avaliações foram feitas por meio do questionário de qualidade de vida NEI-VFQ-25, questionário olho seco específico Ocular Surface Disease Index, tempo de ruptura do filme lacrimal não invasivo, tempo de ruptura do filme lacrimal com fluoresceína, avaliação da superfície ocular com os corantes fluoresceína e rosa Bengala, teste de Schirmer e teste de cristalização do filme lacrimal.
Resultados: Houve melhora estatisticamente significante na qualidade de vida medida pelo questionário NEI-VFQ-25 e no desconforto ocular avaliado pelo Ocular Surface Disease Index, após o tratamento. Todos os testes clínicos sofreram influência favorável e estatisticamente significante durante a fase de tratamento com pilocarpina oral. Em relação à análise de amostras de lágrimas, ocorreram alterações estruturais indicando melhora no padrão de cristalização do filme lacrimal. Os efeitos colaterais com o uso de pilocarpina foram relatados por 96,8% dos pacientes com a pilocarpina e 56,2% com placebo. Sudorese foi o efeito colateral mais frequentemente relatado (pilocarpina = 67,74%; placebo = 11,11%).
Conclusões: O uso oral de pilocarpina na dose diária de 20mg foi capaz de aliviar as queixas de desconforto relacionadas ao ressecamento ocular em pacientes com síndrome de Sjögren, produzir impacto positivo na qualidade de vida dos pacientes e induzir mudanças estruturais favoráveis no filme lacrimal, embora os efeitos colaterais relatados tenham ocorrido com alta frequência.
Keywords: Olho seco; Pilocarpina/uso terapêutico; Síndrome de Sjögren/tratamento farmacológico; Lágrimas
Abstract
Objetivo: Avaliar as alterações da superfície ocular em pacientes com Rosácea, e comparar com grupo controle.
Métodos: Noventa e três indivíduos foram selecionados para este estudo transversal, observacional e não intervencionista, dividido em dois grupos: rosácea (n=40) e controles (n=53). Foram avaliados parâmetros objetivos da superfície ocular (hiperemia conjuntival, estabilidade e volume do filme lacrimal, disfunção da glândula meibomiana, doença do olho seco, coloração da superfície ocular) e comparado indivíduos saudáveis com pacientes com rosácea.
Resultados: 69,23% dos indivíduos com rosácea eram mulheres, com média de idade de 47,34 ± 12,62 anos. Em comparação com controles pareados, não foram evidenciadas diferenças estatisticamente significativas em relação à acuidade visual (p=0,987) e parâmetros do filme lacrimal (altura do menisco lacrimal (p=0,338), tempo de ruptura do filme lacrimal não invasivo (p=0,228), tempo invasivo de ruptura (p=0,471) e teste de Schirmer (p=0,244), bem como hiperemia conjuntival (p=0,106) e coloração com fluoresceína (p=0,489). Associação significativa foi encontrada na avaliação da meibografia (p=0,026), integridade da camada mucosa (p=0,015) e sintomas de superfície ocular (p<0,0001). Pacientes com rosácea também apresentaram alterações importantes na borda palpebral: expressibilidade glandular (p<0,001), padrão de secreção glandular (p<0,001) e telangiectasia (p<0,001).
Conclusão: A disfunção da glândula de Meibômio está frequentemente associada a condições dermatológicas e é caracterizada por achados morfológicos na meibografia, bem como comprometimento da secreção lipídica que leva ao olho seco evaporativo e alterações da superfície ocular e inflamação.
Keywords: Rosácea/complicações; Disfunção da glândula tarsal; Túnica conjuntiva; Síndromes do olho seco; Técnicas de diagnóstico oftalmológico.
Abstract
PURPOSE: To evaluate whether specific meibomian gland morphological features can serve as diagnostic indicators of dry eye disease in patients with type 2 diabetes mellitus.
METHODS: This cross-sectional study included patients with type 2 diabetes mellitus and age-matched healthy controls. All participants underwent a comprehensive ocular surface evaluation, including the ocular surface disease index, tear break-up time, Schirmer’s I test, corneal staining, eyelid margin scoring, meibum expressibility assessment, meibography scoring, and evaluation of meibomian gland loss area. Meibomian gland morphology was assessed bilaterally. Dry eye severity was determined based on ocular surface disease index scores, tear break-up time, Schirmer’s test results, and corneal staining scores. Correlations between meibomian gland features and ocular surface parameters, age, diabetes duration, and hemoglobin A1c levels were analyzed. Receiver operating characteristic analysis was performed to determine the diagnostic value of specific meibomian gland features for dry eye disease.
RESULTS: Dry eye disease was diagnosed in 56.6% of patients with diabetes and 22.6% of controls. Compared with controls, patients with diabetes had significantly higher ocular surface disease index scores, greater corneal staining, worse meibum expressibility, increased meibomian gland loss, and lower tear break-up time and Schirmer values (all p<0.05). Meibomian gland dropout, shortening, tortuosity, distortion, overlapping, ghost glands, and lack of extension to the lid margin were significantly more prevalent in patients with diabetes (p<0.05) and showed significant correlations with age, HbA1c levels, and diabetes mellitus duration. Receiver operating characteristic analysis identified meibomian gland dropout, ghost glands, shortening, and lack of extension to the lid margin as the most predictive morphological features for dry eye disease in patients with diabetes.
CONCLUSION: Type 2 diabetes mellitus is associated with distinct meibomian gland morphological alterations that correlate with both dry eye disease severity and systemic diabetic parameters, suggesting potential diagnostic value.
Keywords: Diabetes mellitus; dry eye syndromes/diagnosis; Meibomian glands/diagnostic imaging; Meibomian gland dysfunction; type 2/complications
Abstract
PURPOSE: This cross-sectional study compared best-corrected visual acuity obtained using Cloudscaper symbols, a novel optotype developed according to ETDRS specifications for children's virtual screening, with that obtained using LEA symbols.
METHODS: A total of 560 children aged 3-16 yr underwent visual acuity test with both Cloudscaper symbols and LS. The test application was standardized using the EyeSpy algorithm. Additionally, 147 participants were tested with the standard Snellen E paper chart. Paired t tests were performed to assess the clinical significance of logMAR visual acuity differences.
RESULTS: The mean logMAR visual acuity with LEA symbols was 0.12 (standard deviation [SD]=0.18; range, -0.10 to 0.80), while with Cloudscaper symbols it was 0.18 (SD=0.19; range, -0.10 to 0.80). The mean difference between Cloudscaper symbols and LEA symbols was 0.099 logMAR (approximately 0.5 optotypes; SD=0.08; range, 0.0-0.14; p<0.0001). Cloudscaper symbols slightly underestimated visual acuity compared to LEA symbols. Visual acuity measured by both methods was highly correlated (Spearman's r=0.74, p<0.0001). The mean visual acuity difference between Cloudscaper symbols and the Snellen E chart was 0.0045 (p=0.805; 95% confidence interval [95% CI]), whereas the difference between LEA symbols and Snellen E was 0.0883 (p<0.001; 95% CI).
CONCLUSIONS: Cloudscaper symbols provide a reliable tool for visual screening in children. Although they slightly underestimate visual acuity compared to LEA symbols – a finding also reported when comparing ETDRS letters with LEA symbols – Cloudscaper symbols show strong agreement with Snellen E chart measurements. This suggests that Cloudscaper symbols allow precise visual acuity assessment comparable to the gold standard.
Keywords: Vision screening; Vision tests; Visual acuity; Mobile applications; Eye health; Child health; Diagnostic techniques, Ophthalmological; Child; Preschool child; Adolescent
Abstract
PURPOSE: This pilot study evaluated the diagnostic accuracy of a deep learning model for detecting pterygium in anterior segment photographs taken using smartphones in the Brazilian Amazon. The model’s performance was benchmarked against assessments made by experienced ophthalmologists, considered the clinical gold standard.
METHODS: In this cross-sectional study, 38 participants (76 eyes) from Barcelos, Brazil, were enrolled. Trained nonmedical health workers captured high-resolution anterior segment images using smartphones. These images were analyzed using a deep learning model based on the MobileNet-V2 convolutional neural network. Diagnostic metrics–including sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve–were calculated and compared with the ophthalmologists’ evaluations.
RESULTS: The deep learning model achieved a sensitivity of 91.43%, specificity of 90.24%, positive predictive value of 88.46%, negative predictive value of 92.79%, and an area under the curve of 0.91. Logistic regression revealed no statistically significant association between pterygium and demographic variables such as age or gender.
CONCLUSIONS: The deep learning model demonstrated high diagnostic performance in identifying pterygium in a remote Amazonian population. These preliminary findings support the potential use of artificial intelligence–based tools to facilitate early detection and screening in underserved regions, thereby enhancing access to ophthalmic care.
Keywords: Pterygium/diagnostic imaging; Smartphone; Diagnostic techniques, ophthalmological; Deep learning; Telemedicine; Artificial intelligence; Cross-sectional studies; Brazil/epidemiology
Abstract
PURPOSE: Access to cataract treatment and diagnostic tools continues to be hindered by financial and logistical barriers. Thus, photography-based cataract analysis via portable devices offers a promising solution for the detection of cataracts in remote regions. In this study, the accuracy of a portable device that is based on the Lens Opacities Classification III System for diagnosing cataracts was analyzed.
METHODS: Photographs of the anterior segment of the eye were taken in a low-light environment, and the pupillary region markings were automatically delineated using infrared photography. The captured images were automatically analyzed using a convolutional neural network. The study group included patients with cataracts, and the control group included patients without cataracts.
RESULTS:A total of 270 eyes were analyzed, which included 143 eyes with cataracts and 127 control eyes. A total of 599 photos were analyzed. The isolated nuclear cataract was the most frequently detected subtype (37.5%), followed by a nuclear cataract associated with a cortical cataract (30.3%). The device's accuracy was 88.5% (Confidence intervals (CI), 83.19%–94.69%), specificity was 84.62% (CI 71.79%–97.30%), positive predictive value was 91.78% (CI 74.36%–97.30%), and negative predictive value was 82.50% (CI 74.36%–97.30%).
CONCLUSION: The portable device is a simplified user-friendly cataract screening technique that can interpret results in remote regions. This innovation could mitigate the occurrence of cataract-induced blindness and prevent premature surgical interventions in early-stage cataracts.
Keywords: Cataract/diagnosis; Diagnostic techniques ophthalmological/instrumentation; Optical devices; Equipment and supplies; Eye-tracking technology
Abstract
PURPOSE: To evaluate the effects of a propylene glycol–hydroxypropyl guar nanoemulsion on symptoms and ocular surface parameters in patients with evaporative dry eye.
METHODS: This prospective, single-center, interventional study included patients aged 18–50 years with evaporative dry eye who received a propylene glycol–hydroxypropyl guar nanoemulsion. Participants were instructed to instill the nanoemulsion three times daily for 90 days. Evaluations included the Ocular Surface Disease Index, tear osmolarity, tear meniscus height, lipid layer thickness, noninvasive tear break-up time, fluorescein tear break-up time, corneal fluorescein staining (National Eye Institute Scale), Schirmer’s test I, and meibum quality.
RESULTS: Thirty-three participants were enrolled, and 30 completed the study. The mean age was 36 ± 10 yr, and 73.3% were women. The mean Ocular Surface Disease Index score significantly decreased from 43.1 ± 20 at baseline to 25.2 ± 17 at 3 months (p=0.009). Median corneal fluorescein staining decreased from 2 (IQ range=1–3) to 1 (IQ range 25–75 = 0–1) at the final follow-up (p=0.002). The mean fluorescein tear break-up time increased significantly increased from 3.8 ± 2.1 at baseline to 5.8 ± 2.2 at 3 months (p=0.002). Tear osmolarity decreased significantly (p=0.01) and lipid layer thickness improved markedly (p<0.001). No significant changes were observed in tear meniscus height or noninvasive tear break-up time (p>0.05).
CONCLUSIONS: Treatment with a propylene glycol–hydroxypropyl guar nanoemulsion significantly improved dry-eye symptoms, corneal staining, tear film stability, and lipid layer quality in patients with evaporative dry eye. No adverse events were reported, supporting the safety and efficacy of this formulation.
Keywords: Dry eye syndromes/drug therapy; Meibomian gand dysfunction/drug Dry Eye therapy; Tears; Emulsions; Lubricant eye drops; Nanoparticles; Propylene glycol/therapeutic use; Polysaccharides/ therapeutic use
Abstract
OJETIVOS: O olho seco é uma doença multifatorial, muito comum na prática clínica oftalmológica. A utilização de questionários validados de sintomas de olho seco permite rastrear de maneira mais objetiva essa doença na população geral, avaliar a prevalência dos sintomas e frequência de diagnóstico, permitindo o tratamento precoce e adequado dessa condição. O 5-Item Dry Eye Questionnaire (DEQ-5) é um questionário em inglês que avalia a frequência e a intensidade do desconforto e ressecamento ocular e a frequência do lacrimejamento, já validado no inglês e espanhol, porém não no português até o presente momento. O objetivo deste estudo foi traduzir e validar o questionário DEQ-5 para a língua portuguesa.
MÉTODOS: Foi utilizado o questionário DEQ-5, composto por 5 perguntas simples e diretas - 2 relacionadas ao desconforto ocular, 2 ao ressecamento ocular e 1 ao lacrimejamento. Foi realizada a tradução inicial da versão em inglês para o português por dois tradutores de língua materna portuguesa, seguido de uma avaliação e compilação de uma versão única por um comitê interdisciplinar das versões traduzidas. Em seguida, tal versão foi traduzida de volta para o inglês por 2 indivíduos que possuíam o inglês como primeira língua, seguido de avaliação e comparação com a versão original em língua inglesa pelo mesmo comitê interdisciplinar. Após, a versão final do questionário foi aplicada em 31 voluntários em dois momentos diferentes.
RESULTADOS: A confiabilidade interobservador das 5 perguntas variou de 0,584-0,813 e a correlação de Pearson de 0.755-0.935, sendo o p-valor <0,0001 em todas elas. A consistência interna foi α=0,887. Todas as perguntas apresentaram concordância de moderada a alta.
CONCLUSÕES: A análise estatística dos dados coletados encontrou ótimos índices de concordância - moderada a alta para todas as questões analisadas -, permitindo o uso do DEQ-5 na língua portuguesa em pesquisas e também como forma de triagem para doença de olho seco e acompanhamento dos sintomas.
Keywords: Síndromes do olho seco; Técnicas de diagnóstico oftalmológico; Inquéritos e questionários; Traduções
Abstract
Objetivo: Comparar as diferenças entre a chord aparente µ e o chord real µ.
Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone.
Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord µ real foi 226,21± 128,53 µm e a média do chord µ média foi 278,66 ± 123,90 µm, com diferença média de 52,45 µm (p=0,01).
A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam.
Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.
Keywords: Imagem óptica; Percepção visual; Pupila; Segmento anterior do olho; Córnea; Técnicas de diagnóstico oftalmológico
Abstract
PURPOSE: To quantitatively assess changes in central corneal sensitivity after phacoemulsification and to characterize recovery patterns up to 90 days using standardized esthesiometry.
METHODS: This prospective observational study included 44 patients (88 eyes) undergoing uncomplicated phacoemulsification with intraocular lens implantation. Central corneal sensitivity was measured using a Cochet-Bonnet® esthesiometer preoperatively and at 30 and 90 days postoperatively. Repeated-measures data were analyzed using Friedman and Wilcoxon signed-rank tests (p<0.05). Inter-eye differences were assessed with a paired Wilcoxon test. Individual changes from baseline (Δ30, Δ90) were calculated, and 90-day recovery was categorized according to thresholds aligned with the 5-mm device resolution. Spearman correlation was used to explore associations between age and Δ90.
RESULTS: Corneal sensitivity decreased after surgery. In right eyes, mean sensitivity declined from 41.14 ± 7.77 mm at baseline to 36.82 ± 9.03 mm at 30 days and partially recovered to 38.64 ± 7.73 mm at 90 days. In left eyes, sensitivity decreased from 44.11 ± 6.29 mm to 37.39 ± 9.05 mm at 30 days and recovered to 41.82 ± 7.63 mm at 90 days. Left eyes showed higher sensitivity than right eyes at baseline (p=0.023) and at 90 days (p=0.018). At 90 days, complete or near-complete recovery (within ± 5 mm of baseline) occurred in 73.2% of right eyes and 78.0% of left eyes, while improvement above baseline (≥ +5 mm) occurred in 7.3% and 4.9%, respectively. Age showed weak, nonsignificant correlations with Δ90 (p=−0.14 to −0.19; p>0.2).
CONCLUSION: Phacoemulsification with a 2.75-mm clear corneal incision leads to a temporary reduction in central corneal sensitivity, with partial recovery by 90 days. Recovery patterns vary among individuals, highlighting the value of postoperative sensitivity monitoring to identify atypical trajectories and guide ocular surface care during visual rehabilitation.
Keywords: Phacoemulsification; Cornea/innervation; Ophthalmic nerve/physiology; Optometry/instrumentation; Diagnostic techniques, ophthalmological; Neural regeneration; Visual rehabilitation.
Abstract
Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco.
Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas.
Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292).
Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.
Keywords: Concentração osmolar; Lágrimas; Síndromes do olho seco; Técnicas de diagnóstico oftalmológico
Abstract
A young woman presented at our clinic with sudden visual loss in the right eye, recurrent vertigo, and right-sided tinnitus. We performed a complete ophthalmological evaluation. This revealed effects of the condition on the small arterioles of the peripheral retina. Susac syndrome is characterized by the clinical triad of retinal arteriolar occlusions, cochleovestibular manifestations, and encephalopathy (which can be identified by neuroimaging abnormalities). Early diagnosis and immunosuppressive therapy improved the patient’s visual acuity and the remission of her other symptoms. Hemi-central retinal artery occlusion is an atypical neuro-ophthalmological finding in this disease. However, its identification as a sign of Susac syndrome may facilitate timely diagnosis and accurate treatment.
Keywords: Ophthalmological diagnostic techniques; Retinal artery occlusion; Vertigo; Cerebrovascular disorders; Susac syndrome
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000