Novos achados comparativos de biomicroscopia ultra-sônica entre olhos contralaterais com fechamento angular agudo e olhos glaucomatosos com ângulo estreito

Rafael Vidal Mérula1; Sebastião Cronemberger1; Alberto Diniz Filho1; Nassim Calixto1

DOI: 10.1590/S0004-27492008000600005

RESUMO

OBJETIVO: Comparar características morfométricas entre olhos contralaterais com fechamento angular primário agudo (FAPA) e olhos glaucomatosos ou suspeitos com ângulo estreito (AE). MÉTODOS: Olhos contralaterais de 30 pacientes com FAPA unilateral e olhos de 30 pacientes com AE foram avaliados através da biomicroscopia ultra-sônica (BUS) no claro e escuro. Parâmetros da BUS como a profundidade central de câmara anterior (PCA), distância da abertura angular a 250 µm/500 µm do esporão escleral (AOD250/AOD500), distância entre o processo ciliar e o trabeculado (TCPD) e distância do contato iris-cristalino (ILCD) foram medidos nos quadrantes superior (QS) e inferior (QI). RESULTADOS: Diferenças significativas entre olhos contralaterais de FAPA e olhos com AE foram encontradas na PCA, p<0,001; AOD250 no QS e QI, p<0,001; AOD500 no QS e QI, p<0,001; TCPD no claro, p=0,010 e TCPD no escuro no QS, p=0,031; e TCPD no claro no QI, p=0,010. Diferenças significativas entre exames no claro e escuro realizados em olhos contralaterais com FAPA foram encontradas na ILCD (p=0,009) no QS e ILCD no QI (p=0,006), e em olhos com SE na ILCD no QS (p=0,047) e ILCD no QI (p<0,001). CONCLUSÕES: Olhos contralaterais de FAPA apresentam um segmento anterior mais aglomerado e uma PCA menor que olhos com AE. ILCD diminui em ambos os grupos quando as condições de iluminação mudam do claro para o escuro.

Descritores: Olho; Microscopia; Ultra-sonografia; Biometria; Câmara anterior; Câmara anterior; Segmento anterior do olho; Segmento anterior do olho

ABSTRACT

PURPOSE: To compare morphometric features between fellow acute primary angle-closure (APAC) eyes and glaucomatous or suspect eyes with narrow angle (NA). METHODS: Fellow eyes of 30 patients with unilateral APAC and 30 with NA were evaluated by ultrasound biomicroscopy (UBM) under light and dark conditions. UBM parameters such as anterior chamber depth (ACD), angle opening distance at 250 µm/500 µm from the scleral spur (AOD250/AOD500), trabecular ciliary process distance (TCPD) and iris-lens contact distance (ILCD) were measured in the superior (SQ) and inferior (IQ) quadrants. RESULTS: Significant differences between APAC fellow and NA eyes were found in ACD, P<0.001; AOD250 at SQ and IQ, P<0.001; AOD500 at SQ and IQ, P<0.001; TCPD light, P=0.010 and TCPD dark at SQ, P=0.031; and TCPD light at IQ, P=0.010. Significant differences between light and dark examinations of APAC fellow eyes were found in ILCD (P=0.009) at SQ and ILCD at IQ (P=0.006), and of NA eyes in ILCD at SQ (P=0.047) and ILCD at IQ (P<0.001). CONCLUSIONS: APAC fellow eyes have a more crowded anterior segment and shallower ACD than NA eyes. ILCD decreases in both groups when the illumination conditions change from light to dark.

Keywords: Eye; Microscopy; Ultrasonography; Biometry; Anterior chamber; Anterior chamber; Anterior eye segment; Anterior eye segment