Showing of 1 until 15 from 107 result(s)
Search for: Lens; crystalline; Age factors; Human
Abstract
Objetivo: Rever e discutir os tratamentos disponíveis para neovascularização subrretiniana (CNV) secundária a degeneração macular relacionada a idade (DMRI) com ênfase especial a terapia fotodinâmica (PDT). Métodos: Revisamos artigos publicados a partir de 1974 até 1999 relacionados a DMRI, seus tratamentos dispo- níveis e PDT. Resultados: O tratamento provadamente efetivo mais utilizado para CNV é fotocoagulação com laser o qual não apresenta um impacto expressivo na deficiência visual causada pela DMRI. Técnicas alternativas de prevenção e tratamento estão sob investigação incluindo cirurgias, tratamento farmacológico antiangiogênico e prevenção com fotocoagulação. PDT com Verteporfina demonstrou ser efetiva no fechamento de CNV em nosso modelo experimental. Um estudo clínico inicial demonstrou que uma aplicação única poderia estabilizar a área de CNV subfoveal com componente clássico na maioria dos pacien- tes por até 3 meses. Dados de 12 meses em tratamentos quadrimestrais revelaram que a estabilização da visão, significando melhora, não alteração ou perda de até 3 linhas ocorreu em 61,4% dos pacientes tratados e que estes eram menos susceptíveis a perda visual de 6 ou mais linhas (85%) quando comparados com placebo (76%). Outro estudo clínico está em andamento para analisar o PDT em CNV do tipo oculto. Conclusão: O tratamento para esta devastadora patologia continua desafiador. Estes estudos clínicos demonstraram fechamento inicial do CNV com PDT e interessantes resultados em termos de acuidade visual, embora estes resultados necessitem de comprovação clínica a longo prazo. A terapia fotodinâmica é uma das mais promissoras novas tecnologias para o tratamento de CNV.
Keywords: Terapia fotodinâmica; Degeneração macular relacionada a idade; Neovascularização de coróide
Abstract
Objetivo: Estimar a epidemiologia do pterígio; sua correlação com sintomas de olho seco e com potenciais preditores sistêmicos e oculares.
Métodos: Estudo transversal, de base populacional, no qual foram realizadas visitas domiciliares aleatórias a 600 participantes, com 40 anos ou mais de idade, em Ribeirão Preto-SP (n=420) e Cassia dos Coqueiros-SP (n=180), Brasil. Uma entrevista estruturada com um questionário detalhado foi usada para coletar informações sobre demografia e possíveis fatores de risco. Em um segundo momento, participantes aleatórios com pterígio (n=63) ou não (n=110) foram avaliados quanto a alterações na superfície ocular.
Resultados: A frequência de pterígio em Ribeirão Preto foi de 21%; 15.7% entre as mulheres e 32.1% entre os homens (p=0,0002). Em Cássia dos Coqueiros, essa taxa foi de 19.4%; onde 17.3% eram mulheres e 25.5% eram homens (p=0,28). A média de idade naqueles afetados pelo pterígio foi superior à dos participantes sem pterígio, 65,6 ± 10,5 e 61,2 ± 12,0 anos, respectivamente (p=0,02). Houve uma correlação positiva entre o pterígio e história prévia de radioterapia e quimioterapia (p<0,0001 para ambos). Houve maior coloração de fluoresceína na córnea e maior coloração de lissamina verde na conjuntiva em olhos com pterígio (p=0,0003 e 0,0001, respectivamente).
Conclusão: Encontramos uma alta frequência de pterígio em duas populações adultas brasileiras, principalmente em homens e idosos. Danos na superfície ocular e história prévia de radioterapia e/ou quimioterapia foram associados ao pterígio.
Keywords: Pterígio/epidemiologia; Síndrome do olho seco; Prevalência; Fatores de risco
Abstract
OBJETIVO: Investigar o efeito inibidor da fluorofenidona contra a proliferação e a transição epitélio-mesenquimal induzida pelo fator de transformação do crescimento β2 na linha HLEC FHL 124 e seu mecanismo potencial.
MÉTODOS: Avaliou-se o efeito in vitro da fluorofenidona na proliferação e na transição epitelial-mesenquimal da linha FHL 124 de células epiteliais do cristalino humano. Após tratamento com fluorofenidona nas concentrações de 0, 0,1, 0,2, 0,4, 0,6 e 1,0 mg/mL, a proliferação celular foi medida através de um ensaio de MTT. A viabilidade celular foi avaliada pela atividade da lactato-desidrogenase liberada por células danificadas. As células FHL 124 foram tratadas com diferentes concentrações do fator de transformação do crescimento β2 (0-10 ng/mL) por 24 horas e a expressão de CTGF, α-SMA, COL-I, E-caderina e Fn foram avaliadas por qPCR e Western blot. Após tratamento com 0, 0,2 e 0,4 mg/mL de fluorofenidona, as expressões do fator de transformação do crescimento β2 e de SMADs foram detectadas com PCR em tempo real e Western blot. As expressões do CTGF, α-SMA, COL-I e Fn foram analisadas através de um ensaio imunocitoquímico.
RESULTADOS: A viabilidade das células FHL 124 não foi inibida com concentrações de fluorofenidona menores ou iguais a 0,4 mg/mL após 24 horas de tratamento. Não foi detectada nenhuma citotoxicidade pelo ensaio da lactato-desidrogenase após 24 e 36 horas de tratamento com 0,2 e 0,4 mg/mL de fluorofenidona. O fator de transformação do crescimento β2 aumentou a expressão de mRNA e proteína do CTGF, α-SMA, COL-I e Fn. Porém, a fluorofenidona suprimiu significativamente a expressão de SMADs, CTGF, α-SMA, COL-I e Fn, tanto na ausência quanto na presença de estimulação pelo fator de transformação do crescimento β2.
CONCLUSÕES: A fluorofenidona inibiu significativamente a expressão de SMADs, CTGF, α-SMA, COL-I e Fn em células FHL 124. Devido à ausência de incompatibilidade em lactentes, a fluorofenidona pode vir a se tornar um novo medicamento contra a opacificação capsular posterior em lactentes.
Keywords: Fator de crescimento transformador beta2; Fluorofenidona; Lentes; Catarata; Lactente
Abstract
PURPOSE: Endophthalmitis is one of the most important adverse events after cataract surgery, as it can lead to total vision loss. This study aimed to describe the occurrence of endophthalmitis after phacoemulsification with intraocular lens implantation in patients treated in a community setting in Porto Velho, Rondônia, Brazil.
METHODS: This retrospective cohort study was conducted using a database of 649 medical records of patients who underwent surgery and were followed for three months. Poisson regression analysis was used to estimate relative risks and 95% confidence intervals (95% CIs).
RESULTS: The incidence of confirmed endophthalmitis was 11.94% (95% CI, 9.50-14.76), while the incidence of confirmed and probable cases was 20.50% (95% CI, 17.52-23.73). For confirmed cases, bilateral surgery and the use of lens model 3 were identified as risk factors for endophthalmitis, whereas age over 70 yr and preoperative antibiotic use were protective factors. For confirmed and probable cases, brown and yellow skin color, bilateral surgery, and the use of lens model 3 were also identified as risk factors. Gram-negative bacteria were the predominant etiological agents, and corneal edema was the main clinical manifestation. The mean duration of treatment was eight days, and 27.12% of patients used antibiotics.
CONCLUSION: The incidence observed was substantially higher than that reported in the literature, with a predominance of Gram-negative agents and an association with bilateral surgeries and the Eyeol intraocular lens model. These findings reinforce the need for continuous epidemiological surveillance and the implementation of specific biosafety and infection control protocols during cataract surgery campaigns.
Keywords: Endophthalmitis; Disease outbreaks; Phacoemulsification; Lens implantation, intraocular; Lenses, intraocular; Cataract; Risk factors; Anti-bacterial agents
Abstract
PURPOSE: To examine how ophthalmological features, screen exposure duration, and break habits among office employees affect ocular surface parameters.
METHODS: This single-center cross-sectional study involved two assessments on the same day: one before and one after a visual display terminal task. During the initial assessment, information on screen use was gathered, and refractive error, anterior segment examination, tear breakup time, and Schirmer test measurements were conducted. Participants tracked their screen usage and break durations throughout the day. At the end of the workday, tear breakup time and Schirmer I tests were repeated. Baseline and follow-up results were compared, and regression analysis was performed to identify factors linked to tear breakup time reduction.
RESULTS: The study enrolled 60 female office employees. Their mean screen time was 269.26 ± 70.21 min, with an average break duration of 151.93 ± 46.24 min. Tear breakup time at the second assessment (6.38 ± 2.70) was significantly lower than at baseline (8.62 ± 2.73) (p<0.001), whereas Schirmer test scores showed no significant change (p>0.05). Tear breakup time reduction was noted in 54 participants (90.0%), with a significant association between tear breakup time decrease percentage and screen exposure (p=0.001, r=0.463). Regression analysis showed that uncorrected or undercorrected refractive error was an independent risk factor for a ≥30% tear breakup time reduction, while taking more frequent short breaks (<15 min) acted as a protective factor.
CONCLUSIONS: Taking more frequent short breaks (<15 min) and correcting refractive errors help prevent intra-day tear breakup time decline during visual display terminal use. Structuring breaks to support tear film stability is advisable for occupations that require regular visual display terminal tasks.
Keywords: Tear film; Screen time; Tear breakup time; Office workers; Protective factors; Lacerations; Refractive errors; Risk factors.
Abstract
Objetivos: A microperimetria tem sido usada há vários anos como uma forma de teste de função visual em pacientes com doenças da retina. Os valores normais de microperimetria obtidos com MP-3 ainda não foram totalmente publicados e os valores basais para sensibilidade macular topográfica e correlações com idade e sexo são necessários para estabelecer graus de comprometimento. O objetivo do trabalho é determinar valores para limiares de sensibilidade à luz e estabilidade de fixação usando o MP-3 em indivíduos normais.
Métodos: Trinta e sete voluntários saudáveis (idade: 28-68 anos), submetidos à microperimetria de limiar total usando uma estratégia de escada 4-2 (rápida) com o tamanho de estímulo padrão Goldmann III e 68 pontos de teste posicionados de forma idêntica aos do Humphrey Field Analyzer 10-2 grade de teste. A estabilidade da fixação foi registrada simultaneamente durante o teste de microperimetria. A relação entre a sensibilidade global e a idade foi calculada por meio de análise de regressão linear.
Resultados: A microperimetria foi realizada em 37 indivíduos (74 olhos). A sensibilidade média global foi de 29,01 ± 1,44 dB, intervalo: 26-31 dB. A mediana da sensibilidade central a 2° medida pelo MP-3 foi de 28,5 ± 1,77 dB (ER) e 28,75 ± 1,98 dB (OE). Os valores médios totais de estabilidade da fixação em 2° e 4° foram 80% e 96%, respectivamente. A análise de regressão linear também revelou um declínio de sensibilidade global relacionado à idade por ano de -0,051 dB ± 0,018 (ER) e -0,078 dB ± 0,021 (LE).
Conclusões: A microperimetria realizada com o MP-3 permite um exame automático, preciso e específico da topografia dos limiares de sensibilidade da retina. Os resultados deste estudo fornecem um banco de dados normal e de idade correspondente da microperimetria MP-3.
Keywords: Campos visual; Testes de campo visual; Retina; Microperímetro; Idade.
Abstract
PURPOSE: Although Brazil has a high prevalence of retinoblastoma, there is a lack of epidemiological data on the disease. Thus, in this study, we aimed to evaluate the epidemiological profile of patients diagnosed with retinoblastoma in the ophthalmology department of a pediatric tertiary referral hospital in Ceara, Brazil.
METHODS: A descriptive and cross-sectional study was conducted by retrospectively analyzing the clinical and socioeconomic data from the medical records of pediatric patients followed-up at the hospital between 2007 and 2021. Retinoblastoma was diagnosed on the basis of a fundoscopic or histopathologic examination.
RESULTS: The data of 105 patients were included in the study, and the mean patient age at the time of diagnosis was 1.7 years. Most of the patients were women (50.5%) and hailed from rural areas (57.4%), which was associated with a higher tumor stage. Of the 150 patients, 57.1% initially presented with leukocoria. Ocular hyperemia was associated with more advanced stages of retinoblastoma (p=0.004). Bilateral involvement was observed in 25.7% of the patients and at a significantly younger age (p=0.009). The presence of retinal detachment, vascularized lesions, and vitreous seeds significantly increased the likelihood of requiring enucleation.
DISCUSSION: This study presents an epidemiological description of retinoblastoma in Brazil, which highlights the significance of early detection. Delayed diagnosis is associated with a poorer visual prognosis and higher mortality rate, particularly in patients with unilateral disease. Risk factors for a more severe disease were retinal detachment, vascularized lesions, and vitreous seeds. The correlation between histopathological features and clinical outcomes was limited.
CONCLUSION: Further studies are required to assess the influence of ocular hyperemia, fundoscopic assessment, and histopathologic findings on the prognosis of retinoblastoma. Moreover, it is critical to devise interventions to reduce the time-to-diagnosis in rural areas.
Keywords: Retinoblastoma; Retinal neoplasms; Epidemiology; Prevalence; Risk factors; Delayed diagnosis; Child
Abstract
PURPOSE: The purpose of this study was to assess the clinical factors associated with dacryocystitis and the need for surgical intervention in infants with congenital dacryocystocele.
METHODS: This retrospective study included 26 infants diagnosed with congenital dacryocystocele and divided them into two groups: complicated-congenital dacryocystocele (with dacryocystitis or preseptal cellulitis) and uncomplicated-congenital dacryocystocele (without infection). Demographic and perinatal characteristics such as age at diagnosis, gender, birth weight, gestational age, delivery method, and laterality were compared between the groups. For an uncomplicated-congenital dacryocystocele, treatment included conservative management and intravenous antibiotics, followed by probing with intraoperative nasal endoscopy and endonasal marsupialization for a complicated-congenital dacryocystocele.
RESULTS: Of the 26 infants, 14 (53.8%) had complicated-congenital dacryocystocele, while 12 (46.2%) had uncomplicated-congenital dacryocystocele. There were no significant differences between the groups in terms of demographic or perinatal characteristics (p>0.05). Surgical intervention was necessary for all complicated-congenital dacryocystocele cases (100%) and two uncomplicated-congenital dacryocystocele cases (16.7%; p<0.001). During a 6-month median follow-up period, all patients demonstrated complete clinical recovery with no intraoperative complications.
CONCLUSION: In conclusion, approximately half of infants with congenital dacryocystocele developed infection-related complications. While perinatal factors were similar across groups, infectious presentation was linked to the need for surgical intervention. These findings suggest that early detection, prompt conservative management, and close follow-up can help reduce the risk of dacryocystitis and the need for surgery.
Keywords: Dacryocystocele; Dacryocystitis; Lacrimal duct obstruction; Marsupialization; Postoperative complication; Gestational age
Abstract
Objetivo: O efeito regulador do microRNA em doenças tem sido confirmado, e este artigo tentou avaliar a expressão do microRNA-210-3p na catarata relacionada à idade e avaliar o efeito da expressão anormal do miR-210-3p em células SAR01/04 induzidas por H2O2.
Métodos: O método de transcrição reversa seguida de reação em cadeia da polimerase (RT-PCR) quantitativa foi realizado para avaliar os níveis de miR-210-3p em amostras de humor aquoso. Análise de características operacionais do receptor foi feita para avaliar a capacidade de discriminação do miR-210-3p entre pacientes com catarata relacionada à idade e pessoas saudáveis. A análise de correlação de Pearson identificou a correlação do miR-210-3p e índices de estresse oxidativo, como superóxido dismutase, glutationa peroxidase, malonaldeído. O ensaio de contagem de células kit-8 (cck-8) e o ensaio no sistema Transwell foram utilizados para estimar a função biológica do formato de células de catarata relacionada com a idade induzida por H2O2. Os níveis de índices de estresse oxidativo como superóxido dismutase, glutationa peroxidase e malonaldeído foram detectados para avaliar o grau de dano do estresse oxidativo em formato de células de catarata relacionada à idade. A relação entre miR-210-3p e seu gene alvo foi verificada por análise do gene repórter luciferase.
Resultados: A expressão miR-210-3p foi elevada no humor aquoso de pacientes com catarata relacionada à idade. A expressão miR-210-3p altamente expressiva mostrou alto valor diagnóstico para catarata relacionada à idade e foi significativamente associado ao nível de marcadores de estresse oxidativo em pacientes com catarata relacionada à idade. A inibição de miR-210-3p pode reverter a estimulação do estresse oxidativo e os efeitos adversos da função celular induzida por H2O2.
Conclusões: Esses dados sugeriram que a expressão miR-210-3p poderia promover a viabilidade celular, migração celular e estresse oxidativo ao direcionar genes ATG 7 relacionados à autofagia em modelo in vitro de células de catarata relacionadas à idade.
Keywords: Catarata; Fatores etários; Humor aquoso; MiR-210- 3p; Estresse oxidativo; Proteína 7 relacionada à autofagia
Abstract
Analisamos as amostras das cápsulas anteriores do cristalino de uma paciente com esclerose sistêmica e comparamos com as de um paciente controle. Não foram observadas diferenças significativas entre esclerose sistêmica e controle nos resultados da coloração com hematoxilina-eosina e picrosirius. Nas amostras obtidas da esclerose sistêmica e do controle, obtivemos expressão de caspase, uma molécula expressa na morte celular por apoptose. A heparinase foi expressa de forma mais marcante na amostra de esclerose sistêmica quando comparada ao controle. Portanto, a cápsula anterior do cristalino da paciente com esclerose sistêmica provavelmente foi afetada pela doença, uma vez que mostrou expressão aumentada de heparinase 1.
Keywords: Cápsula do cristalino; Escleroderma sistêmico; Heparinase; Heparina Liase
Abstract
Este é o relato do caso de um homem de 68 anos que procurou nosso ambulatório para exames de rotina. Quinze meses antes, ele havia se submetido a uma cirurgia conjunta de catarata e buraco macular idiopático de espessura total em seu olho direito, em outra instituição. Durante a consulta em nosso ambulatório, a melhor acuidade visual corrigida no olho direito era de contagem de dedos. O exame do fundo evidenciou um buraco macular idiopático de espessura total naquele olho, o que foi confirmado por uma tomografia de coerência óptica de domínio espectral. Uma nova cirurgia foi oferecida, mas o paciente recusou. Vinte e um meses após sua primeira consulta (36 meses após a cirurgia), a tomografia de coerência óptica de domínio espectral revelou o fechamento espontâneo do buraco macular idiopático de espessura total, com uma lacuna na zona elipsoide foveal. Na última consulta, 22 meses após o fechamento do buraco macular idiopático de espessura total, a melhor acuidade visual corrigida foi de 20/25 e a lacuna na zona elipsoide havia diminuído.
Keywords: Perfurações retinianas/cirurgia; Cirurgia vitreorretiniana; Falha de tratamento; Fatores de tempo; Remissão espontânea; Humanos; Relato de caso
Abstract
Relato de uma técnica que combina o implante de uma lente intraocular com fixação intraescleral sem sutura e uma ceratoplastia endotelial da membrana de Descemet em paciente com ceratopatia bolhosa pseudofácica anterior. Foram criados dois túneis esclerais. Foram feitas incisões na córnea e a lente intraocular dobrável foi cortada e removida da câmara anterior. Foi então efetuada uma vitrectomia anterior e uma lente intraocular dobrável de 3 peças foi implantada na câmara anterior. Um dos hápticos da lente intraocular foi pinçado com um fórceps e puxado para fora do túnel escleral. A extremidade do háptico foi cauterizada. Manobras semelhantes foram feitas no outro háptico. Foi preparado um tecido de doador com 8 mm de diâmetro e o tecido endotelial da área receptora foi removido do centro da córnea. O tecido preparado do doador foi injetado na câmara anterior. Após abertura e posicionamento adequados do tecido do doador, foi injetada uma bolha de ar abaixo do tecido. Não foi observada nenhuma complicação pós-operatória durante um mês de acompanhamento.
Keywords: Lâmina limitante posterior; Ceratoplastia penetrante; Implante de lente intraocular; Lentes intraoculares; Esclera/cirurgia; Humanos; Relatos de casos
Abstract
Uma paciente de 38 anos desenvolveu afacia e aniridia secundárias a um trauma, levando à perda da visão. Para melhorar sua visão, um complexo de íris e lente intraocular (Reper®) foi fixado à esclera com a técnica de flange duplo de Canabrava. Houve um aumento satisfatório na acuidade visual do paciente e nenhuma complicação foi observada durante o acompanhamento de 6 meses. A técnica de Canabrava simplifica e melhora a fixação do complexo de íris e lente intraocular na esclera. É uma opção segura que não requer retalhos ou pontos esclerais.
Keywords: Afacia/etiologia; Aniridia; Implante de lente intraocular; Lentes intraoculares; Esclera/cirurgia; Acuidade visual; Humanos; Relatos de casos.
Abstract
Aging and face sagging have many causes, and various techniques are used for treatment, including noninvasive procedures, such as focused ultrasound, which uses the principle of collagen regeneration by coagulative necrosis of the dermis layers using radiofrequency, but this procedure has complications. We reported a case of a 54-year-old female patient who complained of poor visual acuity in her right eye three days after a focused ultrasound facial aesthetic procedure, with the best visual acuity of 20/60. Biomicroscopy of the right eye revealed an acute cataract with three points of fibrosis extending from the posterior to the anterior capsule. The patient underwent phacoemulsification surgery with visual rehabilitation and improved vision of 20/20. We hypothesized that the occurrence of acute cataract was related to the inappropriate use of focused ultrasound.
Keywords: Cosmetic techniques; Skin aging; Rejuvenation; Ultrasonic therapy/adverse effects; High-intensity focused ultrasound ablation/methods; Cataract/etiology; Phacoemulsification; Lens implantation, intraocular; Visual acuity; Humans; Middle age; Female; Case
Abstract
A retinopatia lúpica é uma manifestação clínica do lúpus eritematoso sistêmico no sistema visual. Geralmente assintomática, porém pode ser uma condição ameaçadora à visão. Está intimamente associada à atividade inflamatória do lúpus eritematoso sistêmico e ao aumento da mortalidade. A retinopatia lúpica tem diversas apresentações clínicas, como a microangiopatia lúpica, oclusão vascular, vasculite, retinopatia hipertensiva associada à nefrite lúpica e retinopatia autoimune. A prevalência e os fatores associados à retinopatia lúpica estão bem definidos em algumas partes do mundo. No entanto, esses dados são pouco conhecidos na América Latina, incluindo o Brasil. Como a retinopatia lúpica é geralmente assintomática, sem a fundoscopia de rotina, provavelmente esta é subestimada. O objetivo desta revisão é discutir a epidemiologia e fatores de risco para retinopatia lúpica.
Keywords: Lúpus eritematoso sistêmico/epidemiologia; Doenças retinianas; Fatores de risco
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Arquivos Brasileiros de Oftalmologia
Official publication of Brazilian Council of Ophthalmology - Conselho Brasileiro de Oftalmologia (CBO)
Rua Casa do Ator, 1.117 - 2nd floor - Zip Code: 04546-004
São Paulo - SP, Brazil
TEL: +55 11 3266-4000
E-mail: [email protected]